Sapphire pressure transmitterDetailed product description:

Product Introduction
The installation of GLD-B0806 is simpler than that of ordinary pressure transmitters. In most applications, the installation of B0806 can eliminate the need for instrument installation boxes, condensers, antifreeze insulation layers, etc.
Crystallization, viscosity, and freezing media: For applications involving crystallization, viscosity, and freezing, these will not damage GLD-B0806. Even if blockage or scaling occurs, it can be directly dissolved at high temperatures or even scraped off with a knife.
Vibration environment and pulsating pressure: In vibration environment or high-frequency pressure measurement, it will not affect the measurement accuracy of GLD-B0806, and a split type probe can be used.
High purity and 3A applications: For the semiconductor industry, gas industry, food and pharmaceutical industries, in order to prevent contamination of production processes and process equipment, transmitters are required to be oil-free, non-toxic, high cleanliness, no hygiene dead corners, no O-rings, and no tank filling. The oil-free all titanium alloy welding membrane of GLD-B0806 is very suitable, and GLD-B0806 can provide lightweight probes suitable for small diameter installation and chamber free probes suitable for food applications.
Thermal Engineering:
Boiler and thermal engineering are the advantageous markets for GLD-B0806, especially the LCD display type GLD-B0806 with green high brightness backlight, which can read clearly even in the dark and is very intuitive to install in the boiler room.
Oil and gas pipelines: For long-distance crude oil pipelines, the GLD-B0806 split probe can directly measure high-temperature and viscous crude oil through the insulation layer. Due to the long-term non calibration, explosion-proof and low-power consumption of B0806, it is very suitable for field installation.
GLD-B0806 Sapphire Pressure Transmitter
Technical specifications of B0806 sapphire pressure transmitter
High temperature steam cleaning: High temperature steam is commonly used for cleaning chemical equipment and disinfecting food and pharmaceutical industries.
GLD-B0806 can withstand such high temperatures without damage, thus eliminating the need for on-site operators to remove the transmitter and clean the equipment.
Omitting the diaphragm system: Ordinary transmitters require a diaphragm system when measuring media above 90 ℃, while GLD-B806 can be used up to 175 ℃ without a diaphragm
Low temperature applications: In some high-altitude regions, military warehouses, low-temperature hydraulic systems, cooling systems, using GLD-B806 is very convenient. GLD-B806 can be used up to -55 ℃, and some customers even use it up to -60 ℃
Measurement of fly ash and coal powder: Fly ash is a mixture containing particles, colloids, and water. Coal powder flows through the pipeline by means of a blower, and both applications can use GLD-B806.