Product name: |
1199 Remote intelligent pressure transmitter
|
|
specification: |
|

Zoom in on the image |
|
Category: |
instrumentation and meters
-- Pressure transmitter |
|
Price: |
factory price |
|
Brand: |
Shanghai |
|
Place of Origin: |
China |
|
Available Quantity: |
batch |
|
delivery cycle: |
Spot goods (or inquire by telephone) |
|
| |
Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058 |
91way@163.com
13901609058(Wechat) |
|
|
|
1199 Remote intelligent pressure transmitterDetailed product description:

1199 remote intelligent pressure transmitter
To avoid direct contact between the isolation diaphragm of GP pressure type and DP differential pressure type transmitters and the measured medium, GP/DP remote transmission pressure/differential pressure transmitters can be used.
Remote transmitters are suitable for the following situations:
1. It is necessary to isolate the high-temperature medium from the transmitter;
2. The tested medium has a corrosive effect on sensitive components;
3. Measure suspensions or high viscosity media;
4. The tested medium solidifies or crystallizes due to changes in environment or process temperature;
5. Replace the measured medium and strictly purify the measuring head;
6. The measuring head must be kept hygienic.
Its technical performance indicators can be found in the relevant transmitters
Technical specifications of 1199 remote transmission intelligent transmitter product
The connection between the 1199 remote transmission device and the process can be threaded or flanged. Flange type can be divided into flange type with lower sleeve and offset type (used with standard 3 "-150lb, 300lb flanges). The remote transmission device can be divided into threaded, flange, flat, and plug-in cylinder types.
Technical performance related to remote transmission devices
Working temperature of filling fluid for remote transmission device:
Silicone oil: -29~149 ℃;
Inert liquid: -18~204 ℃;
Pressure limit:
Threaded type: 14MPa;
Flange, plug-in, and flat: flange rated pressure;
Start time: No preheating required, reaction time depends on temperature, pressure, remote transmission mode, capillary length, diameter, and filling
Related to liquids, etc.

Related Products:
Related articles: