HomeYour location:Homeinstrumentation and metersPressure gaugeDifferential pressure transmitter → BCC series capacitive differential pressure transmitter
Column tabs 
Product name: BCC series capacitive differential pressure transmitter
specification: BCC series capacitive differential pressure transmitter
  Zoom Zoom in on the image
Category: instrumentation and meters -- Differential pressure transmitter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


BCC series capacitive differential pressure transmitterDetailed product description:Column tabs
Product Introduction

The BC series transmitter is mainly used to continuously measure the differential pressure, pressure, and liquid level, flow rate, and other parameters of liquids, gases, and vapors, as well as viscous, corrosive, and precipitating fluids. It converts the measured signal into a standard signal output and cooperates with other unit combination instruments or industrial control computers to form industrial automation systems such as detection, recording, and control.

BCC series BCC series capacitive differential pressure transmitter product technical specifications

Target audience: liquids, gases, and vapors;
Measurement range: see table
Output signal: 4-20mADC. (Special can be a four wire system with 0-10mADC output);
Power supply: The power supply is 12-45VDC, and the general working power supply is 24VDC. The load is related to the power supply, and the load capacity at a certain power supply voltage is shown in Figure 1. The relationship between load impedance R and power supply voltage V is R ≤ 50 (V-12);
Indicator: The on-site output indicator has an ammeter, with a linear indication of 0-100% and a square root indication of 0-100%;
Explosion proof: a. Explosion proof type d Ⅱ BT5b. Intrinsic safety type ia Ⅱ CT6;
Range and zero position: externally continuously adjustable;
Positive and negative transfer: The maximum positive transfer is 500% of the minimum calibration range, and the maximum negative transfer is 600% of the minimum calibration range. After positive and negative migration, the upper and lower limits of the range shall not exceed the limit of the range; Absolute pressure: can only migrate positively, with a maximum positive migration of 500% of the minimum calibration range;
Environmental temperature: General transmitter -25 ℃ to+70 ℃; Explosion proof transmitters have a temperature range of -25 ℃ to+60 ℃;
Storage temperature: -40 ℃ to+100 ℃;
Overload pressure: not exceeding 1.15 times the specified pressure, the transmitter will not be damaged;
Volume variable: less than 0.16 cubic centimeters;
Damping time: continuously adjustable within 0.2-1.67 seconds, suitable for micro, low differential pressure, and flange transmitters, with longer damping time;
Start time: 2 seconds, no preheating required; (Under no migration and standard reference conditions, with silicone oil filling and isolation membrane made of 316L stainless steel)
Accuracy level: see Table 1;
Non sensitive area: none;
Stability: not exceeding the accuracy of the transmitter within six months;
Temperature effect: At maximum range (e.g. 0-40KPa in measurement range 3):
Accuracy level 0.2, 0.25 transmitter, zero position range comprehensive error ≤ ± 0.2%/10 ℃. Range code 2 (low differential pressure) multiplied by a factor of 1.5;
Accuracy level 0.5 transmitter, zero range comprehensive error ≤ ± 0.3%/10 ℃. Range code 2 is ≤± 0.45%/10 ℃, and range code 1 (micro differential pressure) is ≤± 0.54%/10 ℃;
Static pressure influence: At maximum range, under the specified maximum working pressure (see Table 1):
Range codes 2, 3, 4, 5, and 6 have accuracy levels of 0.2 and 0.25, with zero position errors of ≤± 0.5% and accuracy levels of 0.5 multiplied by a factor of 1.2;
Range code 1 micro differential pressure transmitter, accuracy level 0.5 zero position error ≤± 1%, high static pressure accuracy level 0.25 zero position error ≤± 2%, accuracy level 0.5 multiplied by a factor of 1.25;
Vibration effect: In any direction, when the vibration frequency reaches 150Hz, the error caused is ± 0.1%/g of the maximum range, and the range code 1 (micro differential pressure) is ± 0.25%/g;
Power supply impact: less than ± 0.005%/V of the output range;
Installation position influence: When the working diaphragm is not installed vertically, a zero position error of no more than 0.25KPa may occur, which can be eliminated by adjusting the zero and has no effect on the range.
Structural materials: For parts in contact with the medium such as pressure chambers, joints, relief valves, isolation diaphragms, etc., please refer to the "Order Model Specification Table" for various models
The bolt is made of carbon steel, galvanized and passivated
The electrical casing is made of low copper aluminum alloy
The surface coating of the electrical casing is epoxy resin filled with silicone oil (if fluorine oil is required, it can be negotiated at the time of ordering)
Pressure connector: There are two types: cone tube female thread connection and ball cone connection. If not specified when ordering, the supply is ball cone connection joint.
Electrical connection port: The thread of the cable connection hole is 1/2NPT.
Weight: Approximately 5Kg (excluding accessories, except for flanged transmitters)

1、 BCC series capacitive differential pressure transmitter variety series

serial number
name
model
Measurement range (continuously adjustable)
Maximum working pressure (MPa)
accuracy
one
BCCDR type
Micro differential pressure transmitter
BCCDR210
0-0.16~1.6KPa
one
zero point five
two
BCCDR410
four
three
BCCDP type
Low differential pressure transmitter
BCCDP220
0-1~6KPa
one
zero point two five
zero point five
four
BCCDP320
two point five
five
BCCDP420
four
six
BCCDP type differential pressure transmitter (including high static pressure transmitter)
BCCDP430
0-6~40KPa
four
zero point two
zero point five
seven
BCCDP630
ten
eight
BCCHP730
twenty-five
zero point two five
zero point five
nine
BCCHP830
thirty-two
ten
BCCDP type high differential pressure transmitter (including high static pressure transmitter)
BCCDP440
0-40~250KPa
four
zero point two
zero point five
eleven
BCCDP640
ten
twelve
BCCHP740
twenty-five
zero point two five
zero point five
thirteen
BCCHP840
thirty-two
fourteen
BCCDP type large differential pressure transmitter (including high static pressure transmitter)
BCCDP650
0-0.16~1MPa
ten
zero point two five
zero point five
fifteen
BCCHP750
twenty-five
sixteen
BCCHP850
thirty-two
seventeen
BCCDP660
0-0.4~2.5MPa
ten
eighteen
BCCHP760
twenty-five
nineteen
BCCHP860
thirty-two
twenty
BCCDP type * double flat flange differential pressure (remote transmission) transmitter
BCCDP332
0-6~40KPa
2.5 (10)
zero point five
twenty-one
BCCDP342
0-40~250KPa
twenty-two
BCCDP type * double insertion flange differential pressure (remote transmission) transmitter
BCCDP334
0-6~40KPa
two point five
zero point five
twenty-three
BCCDP344
0-40~250KPa
twenty-four
BCCDP Type One Flat One Plug Flange Differential Pressure (Remote Transmission) Transmitter
BCCDP335
0-6~40KPa
two point five
zero point five
twenty-five
BCCDP345
0-40~250KPa
twenty-six
BCYGP type
Pressure transmitter
BCYGP120
0-1~6KPa
zero point two five
zero point five
twenty-seven
BCYGP130
0-6~40KPa
twenty-eight
BCYGP140
0-40~250KPa
twenty-nine
BCYGP150
0-0.16~1MPa
thirty
BCYGP160
0-0.4~2.5MPa
thirty-one
BCYGP170
0-1.6~10MPa
thirty-two
BCYGP180
0-4~25MPa
thirty-three
BCYGP190
0-6~40MPa
zero point five
thirty-four
BCULT type flat flange
Level transmitter
BCULT331
0-6~40KPa
two point five
zero point two five
zero point five
thirty-five
BCULT341
0-40~250KPa
thirty-six
BCULT351
0-0.16~1MPa

serial number
name
model
Measurement range (continuously adjustable)
Maximum working pressure (MPa)
accuracy
thirty-seven
BCULT type plug-in type
Flange level transmitter
BCULT333
0-6~40KPa
two point five
zero point two five
zero point five
thirty-eight
BCULT343
0-40~250KPa
thirty-nine
BCULT353
0-0.16~1MPa
forty
BCYGP type*
Single flat flange pressure (remote transmission) transmitter
BCYGP131
0-6~40KPa
zero point five
forty-one
BCYGP141
0-40~250KPa
forty-two
BCYGP151
0-0.16~1MPa
forty-three
BCYGP161
0-0.4~2.5MPa
forty-four
BCYGP171
0-1.6~10MPa
forty-five
BCYGP type*
Single insertion flange pressure (remote transmission) transmitter
BCYGP133
0-6~40KPa
zero point five
forty-six
BCYGP143
0-40~250KPa
forty-seven
BCYGP153
0-0.16~1MPa
forty-eight
BCYGP163
0-0.4~2.5MPa
forty-nine
BCYGP173
0-1.6~10MPa
fifty
BCYAP type absolute pressure transmitter
BCYAP030
0-6~40KPa
zero point two five
zero point five
fifty-one
BCYAP040
0-40~250KPa
fifty-two
BCYAP050
0-0.16~1MPa
fifty-three
BCYAP060
0-0.4~2.5MPa
fifty-four
BCYAP070
0-1.6~10MPa
fifty-five
BCLDP type
Flow Transmitter
BCLDP420
0-1~6KPa
four
zero point two five
zero point five
fifty-six
BCLDP620
six
fifty-seven
BCLDP430
0-6~40KPa
four
fifty-eight
BCLDP630
six
fifty-nine
BCLDP440
0-40~250KPa
four
sixty
BCLDP640
six

*The single-sided capillary length of the remote transmission flange transmitter is divided into five types: 1.5, 3, 4.5, 6, and 7.5m

BCC series capacitive differential pressure transmitter
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference