| Item 1: Explosion proof type, intrinsic safety type |
| unspecified |
| NF1 |
NEPSI Explosion proof Permit: d Ⅱ CT6 Environmental Temperature: -40-60 ℃ Electrical Interface: 1/2NPT Internal Thread |
| JF3 |
JIS Explosion proof Ex ds Ⅱ CT4 |
| JF35 |
JIS Explosion proof Ex ds Ⅱ CT4 |
| FF1 |
FM Explosion proof: Class I, II&III, Zone 1&2, Groups B, C, D, E, F&G NEMA 4X T6 |
| FF15 |
FM Explosion proof: Class I, II&III, Zone 1&2, Groups B, C, D, E, F&G NEMA 4X T6 |
| KF1 |
CENELEC Explosion proof: EEx d Ⅱ C T4, T5, T6 Maximum liquid contact temperature: T4-135 ℃, T5-100 ℃, T6-85 ℃ |
| KF5 |
CENELEC Explosion proof: EEx d Ⅱ C T4, T5, T6 |
| CF1 |
CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI: T4, T5, T6 |
| CF15 |
CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI: T4, T5, T6 |
| NS1 |
NEPSI intrinsic safety license: ia Ⅱ CT4 environmental temperature: -40-60 ℃ electrical interface: 1/2NPT internal thread |
| JS3 |
JIS intrinsic safety Ex ia Ⅱ CT4 |
| FS1 |
FM intrinsic safety license intrinsic safety C1: I-II&III Div, 1&2, Gps, B, C, D, E, F,&G non combustible C1: I-II&III Div, 1&2, Gps, B, C, D, E, F&G |
| KS1 |
CENELEC intrinsic safety license: EEx ia Ⅱ CT4 |
| CS1 |
CSA intrinsic safety license: C1: I-II&III Div, 1&2, GPS, A, B, C, D, E, F&G ENCL: Type4X Temperature C1: T4 |
| FU1 |
Including FF1 and FS1 |
| KU1 |
Including KF1.KS1 and N-type KEMA, N-type EX nAII CT4 |
| CU1 |
Including CF1 and CS1 |
| SU1 |
SAA explosion-proof, intrinsic safety, and non sparking types: Ex d Ⅱ T6/T5/T4 IP67, Exia Ⅱ CT4 IP67, Exn Ⅱ CT4 IP67 |
| KS5 |
CENELEC (KEMA) intrinsic safety explosion-proof: [Entity mode]: EEx ia Ⅱ CT4; [Fisco mode]: EEx ia Ⅱ CT4/EEx ia Ⅱ BT4 | |
| Item 2: Japanese standard explosion-proof joint |
| unspecified |
| G11 |
Electrical Interface: G1/2 Internal Thread Available Cable Outer Diameter: 8.5-11mm 1 piece |
| G12 |
Electrical interface: G1/2 internal thread, available cable outer diameter: 8.5-11mm, 2 pieces | |
| Item 3: Explosion proof sealing joint |
| unspecified |
| G71 |
Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (1 piece) |
| G72 |
Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (1 piece) |
| G81 |
Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (2 pieces) |
| G82 |
Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (2 pieces) | |
| Item 4: Painting: Color change or painting change |
| unspecified |
| P1 |
The color change only applies to the transmitter housing Munsell logo code: N1.5, black |
| P2 |
The color change only applies to the transmitter housing Munsell logo code: 7.5BG4/1.5 green |
| P7 |
The color change is only applicable to the silver metal of the transmitter housing |
|
X1 |
Paint Change Epoxy Resin Baking Paint | |
| Item 5: Lightning Protection Device |
| unspecified |
| A |
Transmitter power supply voltage: 10.5-32V DC (intrinsic safety type: 10.5-30V DC, fieldbus communication: 9-32V DC) Maximum allowable current: 6000A (1X4 μ S), repeated 1000A (1X40 μ S) 100 times | |
| Item 6: Prohibition of oil treatment or prohibition of water and oil treatment |
| unspecified |
| K1 |
Degreasing and cleaning treatment |
| K5 |
Defatting, washing and drying treatment | |
| Item 7: Calibration Unit |
| unspecified |
| D1 |
P correction (Psi unit) |
| D3 |
Bar calibration (bar unit) |
| D4 |
M correction (kgf/cm2) | |
| Item 8: Sealing treatment of SUS630 nut |
| unspecified |
| Y |
Surface coating of SUS630 bolts and nuts for fastening chamber flange (liquid silicone rubber) | |
| Item 9: Non serrated shape |
| unspecified |
| Q |
The flange sealing surface is not serrated (only ANSI flanges) | |
| Item 10: Teflon membrane |
|
| Item 11: Zero point compensation for liquid contact temperature |
| unspecified |
| R |
Compensation range: 80-300 ℃ | |
| Item 12: PVC (vinyl chloride) is not protected outside the capillary tube |
| unspecified |
| V |
The maximum operating temperature is 100 ℃, used in environments where the use of PVC (vinyl chloride) is prohibited | |
| Item 13: Quick Response |
| unspecified |
| F1 |
Refresh time: ≤ 0.125 seconds Response time (including minimum damping time constant): Maximum 0.5 seconds (including isolation diaphragm) | |
| Item 14: PID/LM Function |
| unspecified |
| LC1 |
PID control function, Link Master function | |
| Item 15: When abnormal, set the output to low side or NAMUK NE43 |
| unspecified |
| C1 |
Low side: ≤ -5% (3.2mm) |
| C2 |
(NAMUK NE43) [Output signal 3.8-20.5mA] Fault alarm output -5%, below 3.2mA |
| C3 |
(NAMUK NE43) [Output signal 3.8-20.5mA] Fault alarm output 110%, above 21.6mA | |
| Item 16: Stainless steel amplifier housing |
| unspecified |
| E1 |
Amplifier casing material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M) | |
| Item 17: Gold plated film |
| unspecified |
| A1 |
Gold plating on sealing membrane | |
| Item 18: Accessory Manufacturing Certificate |
| unspecified |
| M06 |
Flange, diaphragm seat, base, insertion cylinder | |
| Item 19: Proof of Stress Test/Leakage Test |
| unspecified |
| T31 |
JIS 10K test pressure 2MPa test fluid: nitrogen retention time 10 minutes |
| T32 |
JIS 20K test pressure 5MPa test fluid: nitrogen retention time 10 minutes |
| T36 |
ANSI/JPI 150 test pressure 3KPa test fluid: nitrogen retention time: 10 minutes |
| T38 |
ANSI/JPI 300 Test Pressure 7MPa Test Fluid: Nitrogen Retention Time: 10 minutes | |