HomeYour location:Homeinstrumentation and metersPressure gaugeDifferential pressure transmitter → EJA118W Diaphragm differential pressure transmitter
Column tabs 
Product name: EJA118W Diaphragm differential pressure transmitter
specification: EJA118N EJA118W EJA118Y EJA118W Diaphragm differential pressure transmitter
  Zoom Zoom in on the image
Category: instrumentation and meters -- Differential pressure transmitter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


EJA118W Diaphragm differential pressure transmitterDetailed product description:Column tabs

1. Introduction to EJA118W Diaphragm Differential Pressure Transmitter:

Sealing diaphragm is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It is connected to the transmitter by a capillary tube filled with fluid. EJA118W, EJA118N, and EJA118Y diaphragm sealed differential pressure transmitters are used to measure the flow rate, liquid level, density, and pressure of gases, liquids, and vapors, and then convert them into 4-20mADC current signals for output. EJA118W, EJA118N, and EJA118Y can also communicate with each other through the BRAN controller, CENTUM CS/μ XL, or HART275 controller for setting and monitoring purposes.

application type model bellows Range (KPa) Maximum work pressure
Differential pressure and liquid level (diaphragm sealed) Convex membrane

EJA118N
EJA118W
EJA118Y

M 2.5-100 Based on flange specifications
Flat membrane
One flat and one convex H 25-500


2. EJA118W Diaphragm Differential Pressure Transmitter Selection List

Basic specification code: EJA118N-DMSJ12GA-AB01-92NN

Item 1: Output signal
-D 4-20mA DC/with digital communication (BRAN protocol)
-E 4-20mA DC/with digital communication (HART protocol)
-F FF fieldbus communication
Item 2: Measurement range (membrane box)
M 2.5-100KPa(250-1000mmH2O)
H 25-500KPa
Item 3: Material of liquid receiving parts

S

(Diaphragm) JIS SUS316L (Tube) JIS SUS316 (Other) JIS SUS316
Item 4: Flange specifications
J1 JIS 10K
J2 JIS 20K
A1 ANSI 150
A2 ANSI 300
P1 JPI 150
P2 JPI 300
D2 DIN PN10/16
D4 DIN PN25/40
G2 GB PN10/16
G4 GB PN25/40
G6 GB PN100
Item 5: Diaphragm protrusion length (X2)
two X2=50mm
four X2=100mm
six X2=150mm
Item 6: Flange size/material
G 100mm(4")/JIS S25C
H 100mm(4")/JIS SUS304
J 100mm(4")/JIS SUS316
Item 7: Material of bolts and nuts
A JIS SCM435
B JIS SUS630
Item 8: Filling solution
-A Generally used (silicone oil) [contact temperature] -10-250 ℃ [ambient temperature] -10-60 ℃
-B Generally used (silicone oil) [contact temperature] -30-180 ℃ [ambient temperature] -15-60 ℃
-C High temperature use (silicone oil) [contact temperature] 10-300 ℃ [ambient temperature] 10-60 ℃
-D Prohibited oil use (fluorine oil) [contact temperature] -20-120 ℃ [ambient temperature] -10-60 ℃
-E Low temperature (ethylene glycol) [contact temperature] -50-100 ℃ [ambient temperature] -40-60 ℃
Item 9:-

B

Always for B
Item 10: Capillary length (m)
01 Capillary length of 01m
02 Capillary length 02m
03 Capillary length of 03m
04 Capillary length 04m
05 Capillary length 05m
06 Capillary length 06m
07 Capillary length 07m
08 Capillary length 08m
09 Capillary length 09m
ten Capillary length 10m
Item 11: Installation Method

-9

Horizontal piping connection, high pressure on the left side, capillary tube leading out from the front
Item 12: Electrical Interface
0 G1/2 internal thread, one electrical interface
two 1/2NPT internal thread, two electrical interfaces, no blind plugs
three Pg13.5 internal thread, two electrical interfaces, no blind plugs
four M20 internal thread, two electrical interfaces, no blind plugs
five G1/2 internal thread, two electrical interfaces, one blind plug
seven 1/2NPT internal thread, two electrical interfaces, one blind plug
eight Pg13.5 internal thread, two electrical interfaces, one blind plug
nine M20 internal thread, two electrical interfaces, one blind plug
Item 13: Hidden Display Table
D Digital display table
E Digital display table with measurement range setting button
N
Item 14: Installing the bracket
A JIS SECC 2 "pipe installation (flat bracket shape)
B JIS SUS304 2 "pipe installation (flat bracket shape)
N


3. Additional features

Item 1: Explosion proof type, intrinsic safety type
unspecified
NF1 NEPSI Explosion proof Permit: d Ⅱ CT6 Environmental Temperature: -40-60 ℃ Electrical Interface: 1/2NPT Internal Thread
JF3 JIS Explosion proof Ex ds Ⅱ CT4
JF35 JIS Explosion proof Ex ds Ⅱ CT4
FF1 FM Explosion proof: Class I, II&III, Zone 1&2, Groups B, C, D, E, F&G NEMA 4X T6
FF15 FM Explosion proof: Class I, II&III, Zone 1&2, Groups B, C, D, E, F&G NEMA 4X T6
KF1 CENELEC Explosion proof: EEx d Ⅱ C T4, T5, T6 Maximum liquid contact temperature: T4-135 ℃, T5-100 ℃, T6-85 ℃
KF5 CENELEC Explosion proof: EEx d Ⅱ C T4, T5, T6
CF1 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI: T4, T5, T6
CF15 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI: T4, T5, T6
NS1 NEPSI intrinsic safety license: ia Ⅱ CT4 environmental temperature: -40-60 ℃ electrical interface: 1/2NPT internal thread
JS3 JIS intrinsic safety Ex ia Ⅱ CT4
FS1 FM intrinsic safety license intrinsic safety C1: I-II&III Div, 1&2, Gps, B, C, D, E, F,&G non combustible C1: I-II&III Div, 1&2, Gps, B, C, D, E, F&G
KS1 CENELEC intrinsic safety license: EEx ia Ⅱ CT4
CS1 CSA intrinsic safety license: C1: I-II&III Div, 1&2, GPS, A, B, C, D, E, F&G ENCL: Type4X Temperature C1: T4
FU1 Including FF1 and FS1
KU1 Including KF1.KS1 and N-type KEMA, N-type EX nAII CT4
CU1 Including CF1 and CS1
SU1 SAA explosion-proof, intrinsic safety, and non sparking types: Ex d Ⅱ T6/T5/T4 IP67, Exia Ⅱ CT4 IP67, Exn Ⅱ CT4 IP67
KS5 CENELEC (KEMA) intrinsic safety explosion-proof: [Entity mode]: EEx ia Ⅱ CT4; [Fisco mode]: EEx ia Ⅱ CT4/EEx ia Ⅱ BT4
Item 2: Japanese standard explosion-proof joint
unspecified
G11 Electrical Interface: G1/2 Internal Thread Available Cable Outer Diameter: 8.5-11mm 1 piece
G12 Electrical interface: G1/2 internal thread, available cable outer diameter: 8.5-11mm, 2 pieces
Item 3: Explosion proof sealing joint
unspecified
G71 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (1 piece)
G72 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (1 piece)
G81 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (2 pieces)
G82 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (2 pieces)
Item 4: Painting: Color change or painting change
unspecified
P1 The color change only applies to the transmitter housing Munsell logo code: N1.5, black
P2 The color change only applies to the transmitter housing Munsell logo code: 7.5BG4/1.5 green
P7 The color change is only applicable to the silver metal of the transmitter housing

X1

Paint Change Epoxy Resin Baking Paint
Item 5: Lightning Protection Device
unspecified
A Transmitter power supply voltage: 10.5-32V DC (intrinsic safety type: 10.5-30V DC, fieldbus communication: 9-32V DC) Maximum allowable current: 6000A (1X4 μ S), repeated 1000A (1X40 μ S) 100 times
Item 6: Prohibition of oil treatment or prohibition of water and oil treatment
unspecified
K1 Degreasing and cleaning treatment
K5 Defatting, washing and drying treatment
Item 7: Calibration Unit
unspecified
D1 P correction (Psi unit)
D3 Bar calibration (bar unit)
D4 M correction (kgf/cm2)
Item 8: Sealing treatment of SUS630 nut
unspecified
Y Surface coating of SUS630 bolts and nuts for fastening chamber flange (liquid silicone rubber)
Item 9: Non serrated shape
unspecified
Q The flange sealing surface is not serrated (only ANSI flanges)
Item 10: Teflon membrane

unspecified

Item 11: Zero point compensation for liquid contact temperature
unspecified
R Compensation range: 80-300 ℃
Item 12: PVC (vinyl chloride) is not protected outside the capillary tube
unspecified
V The maximum operating temperature is 100 ℃, used in environments where the use of PVC (vinyl chloride) is prohibited
Item 13: Quick Response
unspecified
F1 Refresh time: ≤ 0.125 seconds Response time (including minimum damping time constant): Maximum 0.5 seconds (including isolation diaphragm)
Item 14: PID/LM Function
unspecified
LC1 PID control function, Link Master function
Item 15: When abnormal, set the output to low side or NAMUK NE43
unspecified
C1 Low side: ≤ -5% (3.2mm)
C2 (NAMUK NE43) [Output signal 3.8-20.5mA] Fault alarm output -5%, below 3.2mA
C3 (NAMUK NE43) [Output signal 3.8-20.5mA] Fault alarm output 110%, above 21.6mA
Item 16: Stainless steel amplifier housing
unspecified
E1 Amplifier casing material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M)
Item 17: Gold plated film
unspecified
A1 Gold plating on sealing membrane
Item 18: Accessory Manufacturing Certificate
unspecified
M06 Flange, diaphragm seat, base, insertion cylinder
Item 19: Proof of Stress Test/Leakage Test
unspecified
T31 JIS 10K test pressure 2MPa test fluid: nitrogen retention time 10 minutes
T32 JIS 20K test pressure 5MPa test fluid: nitrogen retention time 10 minutes
T36 ANSI/JPI 150 test pressure 3KPa test fluid: nitrogen retention time: 10 minutes
T38 ANSI/JPI 300 Test Pressure 7MPa Test Fluid: Nitrogen Retention Time: 10 minutes

EJA118W Diaphragm differential pressure transmitter
Product Category