ZCLZ Pneumatic Knife Gate ValveDetailed product description:Column tabs
ZCLZ Pneumatic Knife Gate Valve

Product Features
The principle of combining excellent performance of Chinese and Western gate valves is widely used
The cylinder mechanism performs reliable U-shaped sealing to avoid leakage

Overview
Pneumatic knife type gate valves can complete the action control and signal output of opening and closing positions by using accessories such as solenoid valves and proximity switches, as well as automatic control of continuous actions. Users can choose according to their actual needs.
The variety of pneumatic knife type gate valves is complete. The main body is made of cast iron, cast steel, stainless steel, etc. The diameter ranges from DN50 to DN1000. The product is widely used in chemical, coal, sugar, sewage, papermaking and other fields, and is an ideal sealing valve. Especially suitable for the paper industry to regulate and throttle pipelines.

Main Structure and Characteristics
This valve is mainly composed of left and right valve bodies, U-shaped sealing rings, gate plates, steel nuts, valve stems, brackets, cylinders, and other components. The opening and closing of the valve is completed by the action of the cylinder.
1. Adopting a clip on structure, it has a small volume and light weight;
2. A completely open channel can prevent the medium from depositing inside the valve.
3. The newly developed U-shaped sealing ring can ensure good sealing performance of the valve;
4. Small flow resistance, easy installation and maintenance.
5. The external sealing of the gate is achieved by a sealing strip with elasticity embedded in the valve body, which can be adjusted with the help of screws and pressure plates.

Main component materials

Serial number
Part Name
Material
Serial number
Part Name
Material
Remark
one
valve body
HT250
five
support
Note 1: The grade of rubber depends on the medium and temperature.
2: The material of the gate depends on the composition of the medium.
two
Seal ring
Rubber (Note 1)
six
valve stem
three
ram
Stainless steel (Note 2)
seven
nut
ZHMn58-2-2
four
Sealing strip
Polytetrafluoroethylene
eight
handwheel
QT40-17

Valve selection and drive device model configuration table
1. A cylinder is a device that uses compressed air as a medium to convert its energy into mechanical energy and achieve linear motion. It is widely used as an actuator in various pneumatic systems and is a fundamental component for achieving industrial automation.

Valve diameter DN
Cylinder specifications (cylinder diameter x stroke)
Valve diameter DN
Cylinder specifications (cylinder diameter stroke)
fifty
Φ65×50
two hundred
Φ160×200
sixty-five
Φ65×65
two hundred and fifty
Φ200×250
eighty
Φ80×80
three hundred
Φ200×250
one hundred
Φ100×100
three hundred and fifty
Φ220×350
one hundred and twenty-five
Φ125×125
four hundred
Φ250×400
one hundred and fifty
Φ125×150

2. Technical parameters

Cylinder inner diameter (mm)
Φ40
Φ50
Φ63
Φ80
Φ100
Φ125
Φ160
Φ200
Φ250
Theoretical piston force (N)
(Based on a working pressure of 0.4MPa)
thrust
four hundred and ninety
seven hundred and sixty
one thousand two hundred and fifteen
one thousand nine hundred and sixty
three thousand and seventy-seven
four thousand and eight hundred
seven thousand eight hundred and sixty-nine
twelve thousand three hundred and eight
nineteen thousand two hundred and twenty-seven
pull
four hundred and ten
six hundred and eighty
one thousand and thirty
one thousand seven hundred and seventy
two thousand six hundred and seventy-five
four thousand and four hundred
seven thousand three hundred and seventy-nine
ten thousand and thirty-five
eighteen thousand four hundred and sixty-three
working medium
Purified oil mist compressed air
Work pressure (MPa)
0.15-1
Environmental temperature (℃)
-10-+80
relative humidity
ninety-five
Piston movement speed (mm/g)
50-500
Durability (KM)
six hundred

3. Selection range of cylinder stroke

Cylinder bore
Φ40
Φ50
Φ63
Φ80
Φ100
Φ125
Φ160
Φ200
Φ250
Scope of itinerary selection
four hundred
five hundred
eight hundred
eight hundred
one thousand and five hundred
one thousand and five hundred
two thousand
two thousand
two thousand and five hundred

4. Precautions for proper use of cylinders:
(1) The direction of load movement must be consistent with the direction of piston rod movement to avoid twisting of the piston rod.
(2) Use a combination of filters, pressure reducers, and lubricators (F-R-E combination) to adjust air quality and increase service life.
(3) Choose cylinders with output greater than the actual load to avoid danger in case of insufficient air pressure.
(4) Pay attention to the ambient temperature, and the use temperature of piston rings and sealing materials in the cylinder is generally limited to -5 ℃ -+60 ℃.
(5) There is a corrosive gas environment, and PTFE is used as the material for the piston and sealing parts inside the cylinder.
Air consumption required per 1mm travel unit: 1/min

Pneumatic knife type gate valve appearance and connection dimensions

bore
Air pressure kg/cm2
one
two
three
four
five
six
seven
eight
nine
twelve
zero point four four five
zero point six six five
zero point eight eight five
one point one zero four
one point three two four
one point five four three
one point seven six three
sixteen
zero point seven nine two
one point one eight two
one point five seven three
one point nine six three
two point three five two
two point seven four three
three point one three three
twenty
one point two four
one point eight six
two point four five
three point zero seven
three point six eight
four point two nine
four point nine zero
five point five one
six point one three
twenty-five
one point nine four
two point eight nine
three point eight three
four point seven nine
five point seven five
six point seven one
seven point six seven
eight point six one
nine point five seven
thirty
two point seven eight
four point one five
five point five three
six point nine zero
eight point two seven
nine point six four
eleven point zero two
twelve point three nine
thirteen point seven six
thirty-two
three point one eight
four point seven three
six point two eight
seven point eight five
nine point four one
ten point nine eight
twelve point five five
fourteen point one zero
fifteen point six six
forty
four point nine five
seven point four zero
nine point eight three
twelve point two six
fourteen point six nine
seventeen point one six
nineteen point six zero
twenty-two point zero four
twenty-four point four seven
fifty
seven point seven three
eleven point five five
fifteen point three five
nineteen point one five
twenty-two point nine five
twenty-six point eight zero
thirty point six three
thirty-four point four two
thirty-eight point two four
sixty-three
twelve point two seven
eighteen point three four
twenty-four point three seven
thirty point four one
sixty-three point four four
forty-two point five five
forty-eight point six two
fifty-four point five five
sixty point seven one
eighty
nineteen point seven eight
twenty-nine point five seven
twenty-nine point three zero
forty-nine point zero three
fifty-eight point seven six
sixty-eight point six one
seventy-eight point four zero
eighty-eight point one three
ninety-seven point eight five
one hundred
thirty point nine
forty-six point two
sixty-one point four
seventy-six point six
ninety-one point eight
one hundred and seven point two
one hundred and twenty-two point five
one hundred and thirty-seven point seven
one hundred and fifty-two point nine
one hundred and twenty-five
forty-eight point three
seventy-two point two
ninety-six
one hundred and nineteen point seven
one hundred and forty-three point five
one hundred and sixty-seven point five
one hundred and ninety-one point four
two hundred and fifteen point two
two hundred and thirty-eight point nine
one hundred and fifty
sixty-nine point five
one hundred and three point nine
one hundred and thirty-eight point two
one hundred and seventy-two point five
two hundred and six point nine
two hundred and forty-one point two
two hundred and seventy-five point five
three hundred and nine point eight
three hundred and forty-four point one
one hundred and sixty
seventy-nine point one
one hundred and eighteen point three
one hundred and fifty-seven point two
one hundred and ninety-six point one
two hundred and thirty-five
two hundred and seventy-four point four
three hundred and thirteen point six
three hundred and fifty-two point six
three hundred and ninety-one point five
one hundred and eighty
one hundred
one hundred and forty-nine point seven
one hundred and ninety-nine
two hundred and forty-eight point two
two hundred and ninety-seven point five
three hundred and forty-seven point four
three hundred and sixty-nine point nine
four hundred and forty-six point two
four hundred and ninety-five point four
two hundred
one hundred and twenty-three point six
one hundred and eighty-four point eight
two hundred and forty-five point six
three hundred and six point four
three hundred and sixty-seven point two
four hundred and twenty-eight point eight
four hundred and ninety
five hundred and fifty point eight
six hundred and eleven point six

Pneumatic Knife Gate Valve Pneumatic and Electrical Control Function Description
1. The pneumatic knife type gate valve cylinder is controlled by an electromagnetic valve, which can control the gate valve to stay at the upper limit, lower limit, and any position.
2. When the gate valve stays at the upper and lower limit positions, it emits a set of independent signal contacts that are normally open or normally closed. Can be used as a status indicator.
3. When the gate valve stays at the upper and lower limit positions, the limit switch automatically cuts off the power supply to the corresponding control coil of the solenoid valve. When the gate valve stays in the upper and lower limit positions for a long time, the coil of the solenoid valve is not powered, which can avoid coil heating and improve the service life of the solenoid valve, greatly improving reliability.
4. When the gate valve stays in the upper and lower limit positions for a long time; The gas source is cut off, but the pressure of the valve cylinder remains in the cylinder and can be reliably stopped.
5. During the cylinder switching process, if the control power is cut off, the inlet and outlet air of the cylinder are also cut off, and the air pressure of the locked valve cylinder remains in the cylinder. If there is no leakage in the cylinder piston, solenoid valve, and joint, the gate valve can stay in any position for a long time.

Ordering Instructions
1. Product model and name 2, nominal diameter 3, valve body material 4, nominal pressure