YA-2 Type Intrinsic Safety Explosion proof Pressure TransmitterDetailed product description:Column tabs
The YA-2 intrinsically safe explosion-proof pressure transmitter uses imported diffusion silicon pressure chips as sensitive components, with stable and reliable performance and strong overload resistance. High sensitivity, high precision, small size, light weight, easy installation and use. Widely used for pressure and liquid measurement and control of various gases and hydraulic systems in national economic fields such as petroleum, chemical, metallurgical, power, aviation, aerospace, light industry, hydrogeology, etc.

·The YA-2/3 pressure transmitter is an intrinsically safe explosion-proof pressure transmitter with the explosion-proof mark of Exib Ⅱ CT5
·YA-2 Explosion proof Certificate Number: CE032110; Used in conjunction with reusable safety limiters or Zener safety barriers KAS903H.
·Compliant with GB3836.1-2000 "Explosion proof Electrical Equipment for Explosive Gas Environments Part 1: General Requirements".
·Compliant with GB3836.4-2000 "Explosion proof Electrical Equipment for Explosive Gas Environments Part 4: Intrinsic Safety Type 'i'".
·Structural material: 1Cr18Ni9Ti, sensitive element diaphragm material: 316 stainless steel.
·The measuring medium can be a gas or liquid compatible with the structural material.

Main technical indicators
measurement range
gauge pressure 0 ~ 17,35 kPa
0- 0.1 ~ 35 MPa
absolute pressure 0- 0.1 ~ 35 MPa

output signal

4-20mA (two-wire system)

accuracy class

0.2; zero point five

basic error

±0.2; ±0.5 %F.S

return stroke error

±0.16; ±0.4 %F.S

Working temperature range

-10~+70

Temperature compensation range

0~+70

Storage temperature range

-25~+125

Zero temperature influence

±0.02 %F.S/ ℃

Output temperature impact

±0.03 %F.S/ ℃

excitation voltage

12~36 VDC

insulation resistance

one thousand MΩ/100VDC

Safety overload rate

two hundred %F.S

Electrical connection method
connection method Plug socket number Wire color
Input (power) positive terminal one red
Output signal positive terminal two Blue
If the plug socket number or wire color changes, please refer to the sensor calibration certificate for accuracy.

Dimensions of YA-2 intrinsically safe explosion-proof pressure transmitter

YA-2 Type Intrinsic Safety Explosion proof Pressure Transmitter