HomeYour location:Homeinstrumentation and metersPressure gaugeDifferential pressure transmitter → EJAX130A High static pressure differential pressure transmitter
Column tabs 
Product name: EJAX130A High static pressure differential pressure transmitter
specification: EJAX130A High static pressure differential pressure transmitter
  Zoom Zoom in on the image
Category: instrumentation and meters -- Differential pressure transmitter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


EJAX130A High static pressure differential pressure transmitterDetailed product description:Column tabs
The EJAX10A high static pressure differential pressure transmitter is used to measure the liquid, gas, and vapor levels, densities, and pressures, and then convert them into 4-20mADC current signals for output. EJAX130A can also communicate with HART275 handheld devices for setting, monitoring, and other purposes.

Functional specifications
Output: Two wire system, 4-20mADC output, digital communication, programmable linear or square root output mode, HART protocol loaded on 4-20mADC signal.
power supply voltage
10.5-42VDC (working state)
10.5-30VDC (intrinsic safety type)
16.4-42VDC (digital communication)
16.4-30VDC (intrinsic safety type)
Load (when output signal codes are E and S)
0-1335 Ω working state
250-600 Ω digital communication
Environmental temperature: -30-80 ℃ (-22-1760F)
Liquid contact temperature: -40-120 ℃ (-40-2480F)
HART: Multi core twisted pair cables are used for communication distance, with a maximum communication distance of up to 1.5Km. The communication distance varies depending on the cable type.

3、 Performance specifications
Reference accuracy for range adjustment (including linearity, hysteresis, and repeatability from zero): ± 0.075%
Overvoltage impact: ± 0.03% range upper limit/32MPa
Stability: ± 0.1% range upper limit/60 months

EJAX10A High Static Pressure Differential Pressure Transmitter Selection Specification Table

model
Specification Code
explanation
EJAX130A
High static pressure transmitter
output signal
E
4-20mA, HART protocol digital communication (see GS1C22T1CY)
measurement range
(Capsule)
L
M
H
V
1~100kPa
5~500kPa
Material of the liquid receiving part
S
H
M
T
A
D
B
[Main body [Note 2] [Capsule] [Exhaust screw]
SUS316 (Note 1) SUS316L LSU316
SUS316 (Note 1) TANSU316
SUS316 (Note 1) HASSCU316
pipeline connection
0
one
two
three
four
five
Without pipeline connectors (chamber flange with Tcl/4 internal thread)
Process connector with Rcl/4 internal thread and Rcl/2 internal thread
Process connector with 1/4NPT internal thread (Note 5) and process connector with 1/2NPT internal thread (Note 5)
Without pipeline connectors (1/4NPT internal thread on the chamber flange)
Material of bolts and nuts
A
B
C
[Maximum work pressure]
SCM43532MPa (42MPa) (Note 4)
SUS63032MPa (42MPa) (Note 4)
SUH66032MPa (42MPa) (Note 4)
Installation Method
two
three
six
seven
eight
nine
Vertical installation, high pressure on the right side, process connector on top (Note 2)
Vertical installation, high pressure on the right side, process connector installed vertically at the bottom (Note 2), high pressure on the left side, process connector installed vertically at the top (Note 2), high pressure on the left side, process connector installed horizontally at the bottom (Note 2), high pressure on the right side (Note 3)
Horizontal installation, high pressure on the left side (Note 3)
electrical interface
0
two
three
four
G1/2 internal thread, 1 wiring port
1/2NPT internal thread, 2 connection ports Pg13.5 internal thread, 2 connection ports
M20 internal thread, 2 wiring ports
G1/2 internal thread, 2 connection ports, with a blind plug
1/2NPT internal thread, two electrical interfaces, one blind plug Pg13.5 internal thread, two electrical interfaces, one blind plug
M20 internal thread, two electrical interfaces, one blind plug
Display header
D
E
Digital meter head
Digital header with setting button
(No header)
2-inch pipe installation bracket
A
B
C
D
N
SECC flat bracket
SUS304 flat bracket
SECC L-shaped bracket
SUS304 L-shaped bracket
No installation bracket

Example: EJAX130AEMS5A92NN
Note 1: The material of the process connection for the flange of the containment chamber is SCS14A (equivalent to SUS316). Note 2: If necessary, installation bracket "C" or "D" can be specified.
Note 3: If necessary, installation bracket "A" or "B" can be specified.
Note 4: When customers require a working pressure of 42MPa, please specify it when placing an order.
Note 5: The lower limit of ambient temperature and contact temperature is 15 ℃.
The ※ number is the most representative specification in the standard specifications

EJAX130A High static pressure differential pressure transmitter
Product Category