The 8033 series ultrasonic level gauge is a digital level instrument controlled by a microprocessor, which introduces advanced Canadian technology. In measurement, pulsed ultrasonic waves are emitted by sensors (transducers), and the sound waves are reflected by the surface of the liquid (object) and received by the same sensor, which converts them into electrical signals. And the distance between the sensor and the measured liquid (object) is calculated based on the time between the emission and reception of sound waves. The ultrasonic liquid (substance) level meter has automatic power adjustment, gain control, temperature compensation, and adopts advanced detection technology and computer technology to improve the measurement accuracy of the instrument. It has the function of suppressing interference echoes to ensure the authenticity and accuracy of the measurement results. Due to the use of non-contact measurement, the measured medium is almost unrestricted and can be widely applied in various working environments such as water, sewage, cement, acid and alkali, coal powder, mud, alcohol, beverages, pharmaceuticals, etc.
Technical parameters
Power supply: 24V DC/220V AC Optional signals: 4-20mA, 232, 485
Product accuracy: ± 0.5% FS. Optional ± 0.2% FS. Environmental temperature: -30~78 ℃
Optional range: 0-1~35m Wiring: Two wire system, three wire system, four wire system
Installation thread: M66 × 2 Hole size: φ 68~φ 70mm
Dimensions: 200 × 86 × 135 mm Shell Material: Engineering anti-corrosion plastic/PTFE
Relay capacity: 220V AC/50mA. AC contactors or intermediate relays must be added to control high-power equipment
| eight thousand and thirty-three |
Intelligent ultrasonic level gauge (with built-in temperature automatic compensation) |
| eight thousand and thirty-five |
Special shell (borrowed from German EH product shell) |
|
code |
On site liquid level display |
| C |
LCD display (with a range of 3 meters or more) |
| E |
LED digital display (range of 1 meter and below) |
|
code |
Measurement range (depth of liquid level change) |
| one |
1 meter |
| three |
3 meters |
| five |
5 meters |
| eight |
8 meters |
| ten |
10 meters |
| twelve |
12 meters |
| fifteen |
15 meters |
| twenty-five |
25 meters (up to 35 meters for special orders) |
|
code |
power supply |
| A |
24V DC |
| B |
220VAC |
|
code |
Install Connection |
| six |
Standard M66 × 2 threaded connection (standard installation nut) |
| five |
Flange connection DN50 |
| eight |
Flange connection DN65 |
| nine |
Flange connection DN100 |
| 0 |
Special requirements for flange connection customization, with specifications indicated in text |
|
code |
Instrument structure |
| Y |
Integrated (default 24VDC power supply, optional 220VAC power supply) |
| F |
Split type (default 220VAC power supply, optional 24VDC power supply) |
|
code |
Probe material (not in contact with the medium) |
| eight |
Standard |
| nine |
PTFE (resistant to strong acid, strong alkali, salt corrosion) |
|
code |
output signal |
| B |
Standard 4-20mA |
| E |
4-20mA+relay (high and low points) |
| R |
Modbus RTU 485 communication |
| S |
4-20mA+Hart protocol communication |
|
code |
product grade |
| one |
Standard ordinary type |
| five |
High proof IP67 |
|
| 8033 C 5 A 6 Y 8 B 1 Selection Examples |
Product appearance and dimensions

8033 series ultrasonic level gauge