Characteristics of BQG-2118 Zirconia Oxygen Analyzer
The sensor is made of high temperature resistant and corrosion-resistant materials, with good reliability;
Special structural design, no need for an external gas pump, reference gas can self circulate;
The sensor is equipped with a standard gas interface, which can be calibrated and verified during on-site operation, making maintenance convenient;
Adopting microcontroller control and data processing, it has fast response speed, accurate measurement, and stable performance.
Technical parameters of BQG-2118 zirconia oxygen analyzer
Measurement range: 0-20.6% O2;
Accuracy: ≤± 2% FS;
Tested flue gas temperature: ≤ 600 ℃ (low temperature type); 600-800 ℃ (high temperature type);
The range of the measured smoke air multiplication coefficient is 0.1-99;
Response time: ≤ 3 seconds (90% response);
Current output: 0-10mADC or 4-20mADC;
Power supply: 220V ± 10% 50Hz ± 5%;
Working conditions: Environmental temperature: 0-50 ℃;
Relative humidity:<85%;
Heating time of zirconia detector heating furnace: about 20 minutes;
Appearance and hole size
|
type |
Dimensions mm |
Hole size mm (height x width) |
|
Horizontal (H) |
160×80×120 |
one hundred and fifty-two+1×76+1 |
|
Vertical (Z) |
80×160×120 |
seventy-six+1×152+1 |
|
Square (Q) |
160×160×200 |
one hundred and fifty-two+1×152+1 |
|
Wall mounted type (G) |
220 × 170 × 75 (height × width × thickness) |