Product name: FZRN21-12D/T125-31.5 AC high-voltage vacuum load switch fuse combination
specification: FZRN21-12D/T125-31.5 AC high-voltage vacuum load switch fuse combination
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor high-voltage load switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


FZRN21-12D/T125-31.5 AC high-voltage vacuum load switch fuse combinationDetailed product description:Column tabs
1、 Scope of application
The FZRN21-12D/T125-31.5 type wide J internal AC high-voltage true narrow load switch fuse combination is suitable for use in power supply of two or three phase AC 50HZ, rated voltage 12KV. It is used for breaking load current, overload current and short-circuit current, and is particularly suitable for places without oiling, maintenance and frequent operation requirements. The load switch and combination device have obvious isolation faults, can be equipped with grounding knives and motor spring mechanisms with closing capabilities, and can achieve remote control.

2、 FZRN21-12D/T125-31.5 AC High Voltage Vacuum Load Switch Fuse Combination Model and Its Meaning

FZRN21-12D/T125-31.5 AC High Voltage Vacuum Load Switch Fuse Combination Model Description

3、 Structural characteristics
3.1 Basic Structure
This combination electrical appliance is a three-phase linkage structure. (See Figure 1) It mainly consists of a frame (1), a vacuum arc extinguishing chamber (6), a fuse (3) acting as an isolation knife, a grounding knife (9), a trip rotating device (14), and a spring operating mechanism (17). The isolation knife, vacuum arc extinguishing chamber, and grounding knife are fixed to the frame through insulators. The spring operating mechanism is installed on the side panel of the frame.
3.2 Working principle
3.2.1 Operation of vacuum arc extinguishing chamber
The operation mode of the vacuum arc extinguishing chamber that constitutes the electrical appliance adopts an electric spring operating mechanism. You can also manually close the switch by turning the joystick clockwise, and open it manually or electrically.
3.2.2 Operation of opening and closing of isolation knife and grounding knife
There should be reliable interlocking between the vacuum arc chamber, isolation knife, and grounding knife of the composite electrical appliance. The isolation knife is linked with the grounding knife. When the isolation knife is opened to the isolation distance, the grounding knife starts to store energy and close or open. The grounding knife opens first, and the isolation knife closes later. Only when the vacuum arc extinguishing chamber is in the open state, can the isolation knife and grounding knife be operated; When the grounding switch is closed, the vacuum arc extinguishing chamber cannot be operated.
3.2.3 Fuse impact tripping and opening
When the short-circuit current or overload current flows through the main circuit of the composite electrical device in the closed position, at least one of the phase fuses of the fuse will melt, and the impactor will act, hitting the mechanical locking device of the composite electrical device, so that the vacuum arc extinguishing chamber can achieve reliable and fast opening under the action of the opening spring.
The structure and principle of the load switch are the same as the basic machine of the composite electrical device, and there is no fuse item (3) and trip mechanism item (14) in the instrument.

4、 FZRN21-12D/T125-31.5 AC High Voltage Vacuum Load Switch Fuse Combination Unit Appearance and Installation Dimensions

FZRN21-12D/T125-31.5 AC High Voltage Vacuum Load Switch Fuse Combination Unit Outline Dimensional Drawing

5、 Main technical parameters
1. Technical parameters of composite electrical appliances

serial number
Name
unit
parameter
one
rated voltage
KV
twelve
two
rated frequency
Hz
fifty
three
Maximum rated current of fuse
A
one hundred and twenty-five
four
Rated breaking and handover current
A
three thousand one hundred and fifty
five
The opening time of the switch triggered by the fuse
ms
40±5
six
Rated short-circuit breaking current (expected effective value)
KA
thirty-one point five
seven
Rated short-circuit ignition current (expected peak)
KA
fifty
eight
1-minute power frequency withstand voltage;
Vacuum fracture phase, relative ground/isolated fracture
KA
42/48
nine
Lightning impulse withstand voltage: vacuum fracture
Same, relative/isolated fracture surface
KV
75/85
ten
Rated short-circuit closing current (expected peak)
K
2~5

2. Main technical parameters of load switch

serial number
Name
unit
parameter
one
rated voltage
KV
twelve
two
rated frequency
Hz
fifty
three
rated current
A
six hundred and thirty
four
Rated Active load breaking current
A
six hundred and thirty
five
Rated closed-loop breaking current
A
six hundred and thirty
six
50% rated active load breaking current
A
thirty-one point five
seven
Rated cable charging breaking current
A
ten
eight
The breaking capacity of the rated no-load transformer
KVA
one thousand two hundred and fifty
nine
1-minute power frequency withstand voltage;
Narrowly spaced fracture surfaces, relatively isolated fracture surfaces
KV
42/48
ten
Lightning impulse withstand voltage; Vacuum fracture
Phase to phase, relative to ground/isolated fracture
KV
75/85
eleven
Rated short-time withstand current (thermal stability)
KNS
20/4
twelve
Rated peak withstand current (dynamic stability)
KA
fifty
thirteen
Rated short-circuit closing current
KA
fifty
fourteen
Rated current breaking times
time
ten thousand
fifteen
Mechanical lifespan (vacuum arc extinguishing chamber, isolation)
time
1 0000/20000
sixteen
Allowable wear thickness of vacuum arc extinguishing chamber contacts
mm
two
seventeen
Manual operating torque
N.m
four thousand and two hundred

3. Technical parameters for assembly and adjustment of vacuum arc extinguishing chamber

serial number
name
unit
unit
one
contact gap
mm
10±1
two
overrun mm
4±0.5
three
Average closing speed m/s
0.6±0.2
four
Average opening speed (before opening distance reaches 6mm)
m/s
1.1±O.2
five
The opening and closing phases of the two and three phase contacts are different ms
≤2
six
Contact closing bounce time ms
≤2
seven
Distance between charged bodies and relative ground mm
≥125
eight
E、 Main circuit resistance between lower brackets
UQ
≤70

4. Technical parameters of fuses for combination electrical appliances

model
Rated voltage KV
Rated current of fuse A Rated power on/off A
Rated current of melt A
SDLAJ
twelve
forty thirty-one point five 6.3, 10, 16, 20, 25, 31.5, 40
SFLAJ one hundred forty 50, 63, 71, 80, 100
SKLAJ one hundred and twenty-five fifty one hundred and twenty-five


6、 Ordering Notice
Users should indicate when placing an order:
a. Model, name, specification, quantity;
b. The name, specifications, and quantity of spare parts.
c. Operating mechanism model, operating voltage type and rated value.

Installation dimensions of FZRN21-12D/T125-31.5 AC high-voltage vacuum load switch fuse combination

FZRN21-12D/T125-31.5 AC high-voltage vacuum load switch fuse combination