Product name: FN□-24 series indoor high-voltage load switch and fuse combination electrical appliances
specification: FN□-24 series indoor high-voltage load switch and fuse combination electrical appliances
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor high-voltage load switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


FN□-24 series indoor high-voltage load switch and fuse combination electrical appliancesDetailed product description:Column tabs
Technical data of FN □ -24 series indoor high-voltage load switch and fuse combination electrical equipment

serial number explanation unit requirement reference data
one instruction indoor type Indoor
two model
three main circuit resistance
four standard IEC265 IEC 265
five Temperature design is suitable for
maximum temperature
Deg.C +45 =50C
minimum temperature Deg.C -10 -25C
six rated voltage KV twenty twenty-four
seven Maximum operating voltage MskV twenty-four twenty-four
eight rated frequency Hz fifty fifty
nine rated current A four hundred six hundred and thirty
ten Rated segment current kA rms sixteen
ten
twenty
ten
eleven Rated peak current kA peak forty

fifty

twelve Rated single circuit breaking capacity (capacity) kA peak forty fifty
thirteen Maximum breaking capacity A rms Acc.to IEC420 Acc.to IEC420
fourteen Rated main load breaking current capacity (capacity) A rms Acc.to IEC420 six hundred and thirty
fifteen Maximum main action load breaking capacity A rms sixteen six hundred and thirty
sixteen Rated closing and breaking capacity A rms six hundred and thirty
seventeen Rated single pole breaking capacity A rms forty-five six hundred and thirty
eighteen Rated cable charging capacity A rms forty-five fifty
nineteen Grounding breaking capacity A rms
A rms
A rms
fifty-five
thirty-five
twenty Withstand voltage at a power frequency of 50Hz kA rms
kA rms
fifty
sixty
fifty-five
sixty-five
twenty-one Peak values of ground, phase to phase, and insulation voltage kV peak
kV peak
one hundred and twenty-five
one hundred and forty-five
one hundred and forty-five
one hundred and twenty-five
twenty-two mechanical life 2500 operation
twenty-three When any fuse is working, rotate (release) the operating mechanism of the load switch
twenty-four Lever operating handle (up, down)
twenty-five Energy storage operating mechanism using springs
twenty-six Maximum torque during opening/closing N.M.
N.M.
sixty-four
sixty-four
twenty-seven Operating angle Degree eighty
twenty-eight Operating Time Ms thirty-five
twenty-nine Arc ignition time Ms twenty
thirty Arc extinguishing chamber Provided
thirty-one Separate trip coil tripping
type
Operating voltage
Input electrical energy
V
W
two hundred and twenty Epoxy
220v
five hundred and fifty
thirty-two Rated short-time current (impulse) of grounding switch accessories
Withstand peak current
Short circuit breaking ability
power frequency withstand voltage
(Lightning) impulse withstand voltage
spacing

kA rms
kA peak
kA peak
kV
kV
Mm

sixteen 25kA rms
50 kA peak
50kA peak
fifty-five
one hundred and twenty-five
two hundred and seventy-five


FN □ -24 series indoor high-voltage load switch and fuse combination electrical appliance

FN□-24 series indoor high-voltage load switch and fuse combination electrical appliances
Product Category