| Product name: | TC9000-N1 High precision fully digital tension controller | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Tension controller | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
terminal name |
project |
specification | |
|
DC24V+ |
Power supply |
input |
DC24V positive pole, current above 4A. |
|
DCCOM |
DC24V negative pole. | ||
|
OPTO+ |
Optoelectronic isolation power supply input 5-30VDC. | ||
|
OPTO- |
Optoelectronic isolation power supply input negative pole. | ||
|
+UCELL |
output |
5VDC, The positive pole of the tension sensor power supply is connected to the red wire. | |
|
GND |
The negative pole of the tension sensor power supply is connected to a black wire. | ||
|
MI 1 |
digital signal |
input |
Tap control signal input terminal. |
|
MI 2 |
PID gain setting signal input terminal. | ||
|
MI 3 |
backup | ||
|
RUN/STOP |
Run/stop signal input terminal. | ||
|
MIC |
Digital input public terminal. | ||
|
CELL+ |
analog signal |
input |
The input signal terminal of the tension sensor is connected to a white wire. |
|
CELL- |
Tension sensor input signal terminal, connect green wire. | ||
|
ANG1 |
Analog signal 1 input terminal. | ||
|
ANG2 |
Analog signal 2 input terminal. | ||
|
ANGCOM |
Analog input common terminal. | ||
|
0~10V |
output |
Control the output of 0-10VDC for power amplifiers, servo amplifiers, etc. | |
|
0~24V |
Control output 0~24VDC to directly drive magnetic powder clutch/brake, etc. | ||
|
OUTCOM |
The controller outputs a control voltage common terminal. | ||
|
ALMNO |
alarm signal |
output |
Alarm signal output terminal. |
|
ALMCOM |
Alarm signal common terminal. | ||