HomeYour location:HomeHigh voltage electrical appliancesHigh voltage load switchOutdoor high-voltage load switch → FZW16A outdoor isolation vacuum load switch (manual, electric)
Column tabs 
Product name: FZW16A outdoor isolation vacuum load switch (manual, electric)
specification: FZW16A outdoor isolation vacuum load switch (manual, electric)
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Outdoor high-voltage load switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


FZW16A outdoor isolation vacuum load switch (manual, electric)Detailed product description:Column tabs
1、 Purpose and Scope of Application

FZW □ -12/630-20 outdoor AC high-voltage isolation vacuum load switch is an outdoor high-voltage switchgear equipment with three-phase AC 50Hz and rated voltage of 12KV. Suitable for breaking and closing load currents and short-circuit currents in urban or rural distribution systems, equipped with electric mechanisms and controllers, it can be used as a line sectionalizer or automatic sectionalizer. Due to the adoption of a new insulation structure design and vacuum arc extinguishing chamber, this isolated vacuum load switch has a clearly visible isolation fracture after being turned on and off, and also serves as an isolation switch. Due to the use of vacuum arc extinguishing principle, it has the characteristics of large capacity, no filling material, no environmental pollution, no explosion hazard, long electrical life, and maintenance free.

2、 Working principle
1. Normal working state: After the switch is closed, the main flow direction of the load current is: incoming board - isolation contact - outgoing board. The vacuum arc extinguishing chamber completes the closing first, and finally the isolation contact connects to the incoming board, completing the closing.
2. Closing process: The operating mechanism drives the isolation contact to move. The roller first comes into contact with the crank arm contact and rotates it, and then the vacuum arc extinguishing chamber is closed successively. Finally, the isolation contact is connected to the incoming line board, and the closing is completed.
3. Opening process: The operating mechanism drives the isolation contact to first close into the wire board and separate, causing the load current to transfer to the vacuum arc extinguishing chamber. The isolation contact continues to move, causing the vacuum arc extinguishing chamber to open, and then a visible isolation fracture is formed, completing the opening.

3、 Main technical parameters of FZW16A outdoor isolation vacuum load switch (manual, electric)

serial number
project
unit
parameter
one
rated voltage
KV
twelve
two
rated current
A
six hundred and thirty
three
rated
insulation
level
1-minute power frequency withstand voltage Alternating and facing the ground
KV
Dry: 42 Wet: 30
isolation gap
forty-eight
Lightning impulse withstand voltage (peak value) Alternating and facing the ground
seventy-five
isolation gap
eighty-five
four
Rated breaking load current
A
six hundred and thirty
five
Rated short-time withstand current
KA
twenty
six
Rated peak withstand current
fifty
seven
Rated short-circuit current breaking times
fifty
eight
Close rated short-circuit closing current times
time
two
nine
Rated short-circuit duration
S
four
ten
mechanical life
time
one thousand


3、 Ordering Notice
Please specify when placing an order
1. The name, model, rated current, and quantity of the product.
2. Installation method

FZW16A outdoor isolation vacuum load switch (manual, electric) installation size: 600 × 513

FZW16A outdoor isolation vacuum load switch (manual, electric)
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference