The UHZ-52 series magnetic float level gauge is suitable for liquid level measurement in open or pressure vessels. Based on its special design, this instrument is particularly suitable for use in corrosive, harmful, or flammable media and harsh environments. On site liquid level indication does not require power supply. This instrument can also be optionally equipped with an electric remote transmission system and limit switches simultaneously or separately.
Measuring principle
The operating principle of this instrument is the bypass pipeline liquid measurement principle. The measuring tube serves as a bypass container connected to it, so that the various conditions inside the measuring tube are the same as those inside the container. Install a permanent magnet system inside the float to transmit measurement values to the indicator through magnetic coupling. A linear scale strip is installed on the indicator. When the liquid level changes, the magnetic system inside the float drives the magnetic flap or float to indicate the corresponding liquid level value in the container.
Main technical parameters of magnetic float level gauge:
Measurement range: Within the measurement range of 500~8000mm, users can choose freely according to their needs.
On site indication accuracy: ± 10mm
Medium temperature: -80~+120 ℃
Medium density: ≥ 0.45g/cm3
Work pressure: PN1.62.54.06.410.016.0MPa. Pressure ≥ PN10.0MPa, please specify when placing an order.
Medium viscosity: ≥ 1St (10-4/m2/S)
Connection flange: DN20DN25, can be customized according to user requirements.
Characteristics of magnetic float level gauge:
The structure is simple and sturdy. Advanced technology, cutting-edge design.
The pressure resistance, indicating part, and measuring part are sealed and isolated.
Suitable for harsh operating and environmental conditions.
It has reliable function for liquids/liquefied gases with a density of ≥ 0.5kg/l.
Large scale bar for easy reading.
It has different types such as PTFE lining or hard plastic.
Pressure: Standard type ≤ 4.0MPa, medium pressure type 6.4MPa, high pressure type ≤ 10.0MPa \ 16.0MPa.
Temperature: Standard type ≤ 150 ℃, medium temperature type ≤ 200 ℃, high temperature type ≤ 450 ℃.
It is possible to measure the interface between two liquid media with a density difference of ≥ 0.1kg/l.
The indicator can be replaced, with the addition of limit switches and remote transmission systems.
Remote transmission current output 4-20mA. Magnetic float level gauge model code:
UHZ-52/.../../../..-../..
1.2.3.4.5.6.
1. Connection method
C=Horizontal installation (side installation)
D=Vertical installation
E=Bottom side installation (inlet vertical, outlet horizontal)
F=Top side installation (inlet horizontal, outlet vertical)
P=Top installation
2. Material
|
type |
Measurement tube material |
Measurement tube specifications |
Flange material |
Maximum working pressure (MPa) |
Maximum medium temperature (℃) |
|
UHZ-52/R1 |
1Cr18Ni9Ti |
Φ72×2 |
1Cr18Ni9Ti |
four |
two hundred |
|
UHZ-52/R0 |
0Cr17Ni12Mo2Ti |
0Cr17Ni12Mo2Ti | |||
|
UHZ-52/R10 |
0Cr18Ni9Ti |
0Cr18Ni9Ti | |||
|
UHZ-52/R4 |
three hundred and four |
three hundred and four | |||
|
UHZ-52/R4L |
304L |
304L | |||
|
UHZ-52/R6 |
three hundred and sixteen |
three hundred and sixteen | |||
|
UHZ-52/R6L |
316L |
316L | |||
|
UHZ-52/RP* |
316 lined with PTFE |
three hundred and sixteen | |||
|
UHZ-52/PP* |
PP |
Φ63×3 |
PP |
zero point six |
one hundred |
|
UHZ-52/RV* |
PVC |
PVC |
forty | ||
|
UHZ-52/RD* |
PVDF |
PVDF |
one hundred and fifty |
(See float selection for details on float material)
3. Limit switch control point and control form
MC, KD, KS, Ksa (see page 127 for details)
-Exd - K1=lower limit
-K2=upper limit - KK1=upper and lower limits
-KK2=upper and lower bounds - C=single pole single throw normally closed
-O=Single pole single throw normally open -- pc=Single pole single throw normally closed
--Po=single throw, single throw, normally open
4. Electric signal
Es=electric remote transmission type (two-wire system, output 4-20mA) Exi=electric remote transmission type (ExiaICT6, intrinsic safety type)
Exd=Electric Remote Transmission Type (ExdIICT6, Explosion proof Type)
5. Measurement classification
T=Interface detection
6. Additional form of measuring tube
B=Measuring tube with insulation jacket AG=Low temperature type (-40 ℃) TR=Low temperature type (-200 ℃) HR=High temperature type
HP=High pressure type IC-TR=Ultra low temperature type with insulation sleeve IC-HR=High temperature type with insulation sleeve
Technical parameters of magnetic float level gauge:
Users are responsible for strictly adhering to the application and technical regulations of our instruments
| measurement range Reference type UHZ-52/C (D, E, F)/R10.3-6m UHZ-52P/R10.3~2.5m Optional UHZ-52C/R10.3-9m (cannot be used for Ex type) |
| Accuracy ± 10mm |
| Minimum medium density Standard UHZ-52/C (D, E, F)/R10.5~3.0kg/l UHZ-52P/R10.8~3.0kg/l See "Float Selection Table" for other details“ |
| Viscosity ≤ 5000MPa. s |
| Working pressure standard type 4.0MPa, medium pressure type 6.4MPa, high pressure type 10.0MPa, 16.0MPa (Depending on the material, flange rated pressure, and float pressure resistance) |
| Indicator scale unit Standard cm/m linear scale Optional inches/feet,% (or according to user requirements) |
| Indicator anti expansion rating IP65 |
| medium temperature Standard type ≤ 150 ℃ Optional medium temperature type ≤ 200 ℃, high temperature type ≤ 450 ℃, UHZ-52/R1/Exi(Exd)-20℃~60℃ (On site indicator with electric remote transmission device) UHZ-52/R1/(for on-site indication in hazardous areas) -20 ℃~200 ℃ Magnetic flap indicator |
| Connecting flange... according to DIN2501 standard (please request separately from the manufacturer for medium and high pressure) standard form UHZ-52/C(D、E、F)/R1 DN25,PN4.0 UHZ-52/P/R1DN150,PN1.6 UHZ-52/C/RPDN25,PN16 PP,PV,PDDN25,PN0.6 |
| Optional selection UHZ-52/C (D, E, F)/R1 DN15~DN25, PN1.6 or PN4.0 UHZ-52/P/R1DN200,PN1.6 If the device has an access hole, UHZ-52/P/R1 can choose DN40~DN125, PN1.6 UHZ-52/C/RPDN15~DN50,PN1.6 PP, PV, PDDN15-DN50, PN0.6 or PN1.0 Insulation jacket connection flange DN15, DN4.0, PN0.6 or PN1.0 Note: Other flange standards and rated pressures are subject to user requirements. |
| Remote transmission output 4-20mA |
The allowable coefficient of expansion for PVC and PP is 0.12-0.15mm/m ℃.
Magnetic float selection
The selection of a float should consider the effects of liquid pressure, temperature, and density. In addition, when selecting materials, it is necessary to consider the required level of corrosion resistance and the correct use of magnetic steel systems.
| Standard Type | ||||||||||
| UHZ-52/C (D, E, F) magnetic float | ||||||||||
|
float child number |
shape |
Float size specifications |
Float material |
Minimum density of medium |
Maximum work pressure |
medium density | ||||
|
20℃ |
100℃ |
200℃ |
300℃ |
minimum |
highest | |||||
|
mm |
Kg/l |
MPa |
MPa |
MPa |
MPa |
℃ |
℃ | |||
|
one |
cylindrical |
φ64×200×1.0 |
1Cr18Ni9Ti |
zero point eight two |
five |
four point five |
three point seven |
three point two |
-200 |
four hundred |
|
two |
cylindrical |
φ64×200×0.5 |
1Cr18Ni9Ti |
zero point five five |
one point six |
one point two |
one |
zero point nine |
-200 |
four hundred |
|
three |
cylindrical |
φ64×208×0.6 |
Ti |
zero point five |
two |
one point six |
one |
zero point six |
-200 |
three hundred |
|
four |
cylindrical |
φ64×208×1.0 |
Ti |
zero point six |
six |
four |
two point five |
one point six |
-200 |
three hundred |
|
five |
cylindrical |
φ64×120×2.0 |
PVC |
zero point eight five |
two point five |
- |
- |
- |
ten |
forty |
|
six |
cylindrical |
φ64×200×2.0 |
PP |
zero point eight |
three point two |
- |
- |
- |
ten |
eighty |
|
seven |
cylindrical |
φ64×145×2.5 |
PVDF |
zero point nine |
zero point nine |
- |
- |
- |
-40 |
one hundred |
|
UHZ-52/C (D, E, F)/Ex (live remote transmission local indicator) | ||||||||||
|
one |
cylindrical |
φ64×200×1.0 |
1Cr18Ni9Ti |
zero point eight two |
four |
four |
- |
- |
-20 |
one hundred |
|
two |
cylindrical |
φ64×200×0.5 |
1Cr18Ni9Ti |
zero point five five |
one point six |
one point two |
- |
- |
-20 |
one hundred |
|
three |
cylindrical |
φ64×208×0.6 |
Ti |
zero point five |
two |
one point six |
- |
- |
-20 |
one hundred |
|
four |
cylindrical |
φ64×208×1.0 |
Ti |
zero point six |
four |
four |
- |
- |
-20 |
one hundred |
|
UHZ-52/C (D, E, F) local indicator | ||||||||||
|
one |
cylindrical |
φ64×200×1.0 |
1Cr18Ni9Ti |
zero point eight two |
four |
four |
three point seven |
- |
-20 |
two hundred |
|
two |
cylindrical |
φ64×200×0.5 |
1Cr18Ni9Ti |
zero point five five |
one point six |
one point two |
one |
- |
-20 |
two hundred |
|
three |
cylindrical |
φ64×208×0.6 |
Ti |
zero point five |
two |
one point six |
one |
- |
-20 |
two hundred |
|
four |
cylindrical |
φ64×208×1.0 |
Ti |
zero point six |
four |
four |
three |
- |
-20 |
two hundred |
|
UHZ-52/P/R1 magnetic float | ||||||||||
|
one |
sphere |
φ150 |
1Cr18Ni9Ti |
one |
one point six |
one |
-20 |
two hundred | ||
|
two |
sphere |
φ150 |
1Cr18Ni9Ti |
one |
one point six |
one |
-20 |
two hundred | ||
Attention! Float inspection pressure=1.5 times the maximum allowable working pressure. Medium voltage and high voltage; Please request from the manufacturer for medium and high temperature.