| Product name: | S-320 Type Switching Power Supply | ||||||
| specification: | ![]() |
||||||
| Category: | transformer equipment -- switching power supply | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
| ||||||||||
|
model performance |
S-320-5 | S-320-7.5 | S-320-12 | S-320-13.5 | S-320-15 | S-320-24 | S-320-27 | S-320-48 | ||
| DC output voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V | ||
| Output voltage tolerance (Note 2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ||
| Rated output current | 50A | 36A | 25A | 22A | 20A | 12.5A | 11A | 6.5A | ||
| Output current range | 0-50A | 0-36A | 0-25A | 0-22A | 0-20A | 0-12.5A | 0-11A | 0-6.5A | ||
| Ripple and noise (Note 3) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | ||
| Stability of incoming line (Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
| Load stability (Note 5) | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
| DC output power | 250W | 270W | 300W | 297W | 300W | 300W | 297W | 312W | ||
| efficiency | 77% | 80% | 82% | 83% | 84% | 86% | 86% | 87% | ||
| Adjustable range of DC voltage | 4.5-5.7V | 6-9V | 10-13.2V | 12-15V | 13.5-18V | 20-26.4V | 26-32V | 41-56V | ||
| Input voltage range | 100-120VAC/200-240VAC can be selected by the switch as 47-63Hz; 248-370VDC | |||||||||
| input current | 6A/115V 3.5A/230V | |||||||||
| inrush current | 20A/115V 40A/230V | |||||||||
| leakage current | < 3.5mA/240VAC | |||||||||
| overload protection |
115% to 135% cut off output reset: automatic recovery | |||||||||
| overvoltage protection | 5.75-6.75V | 9.4-10.9V | 13.8-16.2V | 15.5-18.2V | 18-21V | 27.6-32.4V | 33.7-39.2V | 57.6-67V | ||
| High-temperature protection | RTH1>=65 ℃ FAN ON.<=55 ℃ FAN OFF.>=70 ℃ Cut off output (5-15V) | |||||||||
| temperature coefficient | ±0.03%/℃(0~50℃) | |||||||||
| Start, rise, and hold time | 2s,20ms,20ms | |||||||||
| seismic resistance | 10-500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis | |||||||||
| pressure resistance |
Input/output room: 3KVAC, input and enclosure: 1.5KVAC, output and enclosure: 0.5KVAC | |||||||||
| Isolation resistor | Between input and output, input and casing, output and casing: 500VDC/100M Ω | |||||||||
| Working temperature and humidity | -10℃~+50℃,20%~90%RH | |||||||||
| Storage temperature, temperature | -20℃~+85℃,10%~95%RH | |||||||||
| Overall dimensions | 215*115*50mm | |||||||||
| weight | 1.15Kg | |||||||||
| safety standards | UL1950,EN60950 | |||||||||
| EMC standard | EN55022,EN55024,EN61000 | |||||||||
| Other Performance | …… | |||||||||
| Note: 1. The above parameter testing conditions are: 230VAC input, rated load, 25 ℃ 70% RH. Humidity. 2. Tolerance: including set tolerance, line stability, and load stability (Note 5). 3. Ripple test: Use A12 "twisted pair for 20MHz and short-circuit with 0.1uF&47uF capacitors for interruption. 4. Incoming voltage stability test: the lowest voltage to the highest voltage of the incoming line at full load. 5. Load stability test: load from 0% to 100%. 6 C3, 4,41 must be dismantled | ||||||||||