HomeYour location:Homeinstrumentation and metersLevel instrumentlevel switch → ZSK series vacuum water intake controller
Column tabs 
Product name: ZSK series vacuum water intake controller
specification: ZSK series vacuum water intake controller
  Zoom Zoom in on the image
Category: instrumentation and meters -- level switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


ZSK series vacuum water intake controllerDetailed product description:Column tabs

The ZSK series vacuum water intake controller is suitable for the vacuum water intake system of centrifugal water pumps. When the vacuum is formed in the evacuated water pump (all air inside the pump casing is expelled), a timely and accurate vacuum formation signal can be sent out to act on the water pump control circuit, in order to achieve linkage control of the centrifugal water pump's vacuum water intake operation mode.   



ZSK series vacuum water intake controller system diagramZSK series vacuum water intake controller structure diagram

Figure 1 (Vacuum Water Diversion System Diagram of Centrifugal Water Pump) Figure 2 (Structure Diagram of Vacuum Water Diversion Controller)

Working principle
During normal operation of the centrifugal water pump vacuum water intake system as shown in Figure 1, valves 1F, 2F, 3F, and 5F are open, while valve 4F is closed. When the water pump draws water, start the vacuum pump, open the ZS solenoid valve, and the air inside the water pump housing is discharged to the atmosphere through 1F, 2F, ZSK-1, ZS, 3F, 5F and the vacuum pump. After the vacuum is formed, the normally open contact in ZYK-1 is closed, the intermediate relay is connected, the vacuum pump is stopped, the solenoid valve is closed, and the water pump is started. If maintenance of ZS solenoid valve and ZSK-1 vacuum water intake controller is required, open valves 1F, 4F, and 5F. Close valves 2F and 3F. When the vacuum is not formed, the floating ball falls and the control contact is in a disconnected state, as shown in the ZSK-1 structural diagram (Figure 2); After a vacuum is formed inside the pump casing, the water inside the pump casing enters the vacuum water intake controller cylinder through 1F and 2F. Raise the float and when it reaches the top, the magnetic ring inside the float acts on the wet reed tube inside the conduit, causing the control contact to close and emitting a vacuum formation signal.  

Main technical parameters of ZSK series vacuum water intake controller
1. Working pressure 0.5Mpa, test pressure 1.0 Mpa
2. Contact capacity: Maximum voltage 220V AC
Maximum current 2A
Maximum disconnect power 100M
3. The control contacts can be connected to 220V AC or DC circuits, and should be connected to the control circuits of vacuum pumps, solenoid valves, water pumps and other equipment through intermediate relay contacts.  

Model

Model number Diameter of inlet and outlet pipes Specifications
ZSK-1/1 Φ25 G1"
ZSK-1/2 Φ38 G1.5"
ZSK-1/3 Φ50 G2"

ZSK series vacuum water intake controller
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference