Product name: FN11-12RD series high-voltage load switch
specification: FN11-12RD series high-voltage load switch
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor high-voltage load switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


FN11-12RD series high-voltage load switchDetailed product description:Column tabs
FN11-12/630-20 indoor AC high voltage load switch (hereinafter referred to as FN11-12D load switch) is a three-phase high voltage starting device with a rated voltage of 12kV and a rated frequency of 50Hz. It is used for switching load current, closed-loop current, no-load transformer and cable charging current, and switching short-circuit current. Load switches equipped with grounding switches can withstand short-circuit currents.  
FN11-12RD/125-31.5 AC high voltage load starting fuse combination (hereinafter referred to as FN11-12 (R) D combination) is an indoor high voltage switchgear that combines FN1112RD load switch with S-port LAJ (XRNT port-10) high voltage current limiting fuse. It can disconnect any current up to the short-circuit current; The load switch disconnects the working current, the fuse disconnects the short-circuit current, and jointly disconnects any current between the working current and the full short-circuit current. At the same time, the fuse causes the load switch to open through its impact.  

Scope of application of FN11-12RD series high-voltage load switch
The FN11-12D/load switch FN11-12RD combination electrical device is mainly used for load control and short-circuit protection in urban distribution stations and industrial electrical equipment powered by three-phase ring networks or terminals. Due to the more reliable protective effect of composite appliances on electrical equipment such as transformers than using circuit breakers, they are particularly suitable for ring networks, radiation replacement units, and box type substations.  

Normal working environment
Using ambient air temperature: upper limit+40 ℃, lower limit -25 ℃;  
Altitude not exceeding 1000M
Relative humidity, with a daily average not exceeding 95% and a monthly average not exceeding 90%;  
The surrounding air should not be significantly polluted by corrosive or flammable gases and water vapor;  
No frequent vigorous exercise;  
Pollution resistance level: Level II;  
If the usage conditions exceed the above regulations, it shall be determined through consultation between the user and the manufacturer.   

Technical parameters and performance of FN11-12RD series high-voltage load switch

serial number
project
unit
FN11-12D/630
FN11-12RD/125
one
rated voltage
kV
twelve
two
rated frequency
Hz
fifty
three
rated current
A
six hundred and thirty
one hundred and twenty-five
four
Lightning impulse withstand voltage
kV
Ground and phase to phase 75, isolation and disconnection 85
five
1-minute power frequency voltage
kV
Ground and phase 42, isolation and disconnection 48
six
Rated thermal stability current
kA
20(4S)
seven
Rated dynamic stable current
kA
fifty
eight
Rated closing current (peak value)
kA
fifty
fifty
nine
Rated short-circuit breaking current (expected value)
kA
thirty-one point five
ten
Maximum 1 ㎡· t when temporarily disconnecting current
A²S
According to the characteristic curve of the fuse
eleven
Minimum breaking current
kA
According to the characteristic curve of the fuse
twelve
Rated transfer current
kA
one point five
thirteen
Maximum breaking current (reference value)
kA
one point eight
fourteen
Disconnect the capacity of the no-load transformer
kva
one thousand two hundred and fifty
fifteen
Rated cable charging current
A
ten
sixteen
Rated active load current breaking times
time
>100
seventeen
Rated active load current switch opening time
S
>0.06
eighteen
Grounding switch thermal stability current
kA
20(2S)
20(2S)
nineteen
Stable current (peak value) of grounding switch
kA
fifty
fifty
twenty
Electric motor operating power supply voltage
V
AC/DC 100, 220

FN11-12RD series high-voltage load switch mechanical characteristic parameters

serial number
project
unit
FN11-12D/630
FN11-12RD/125
one
Total travel of moving contact
mm
200 +8 -2
two
Intermediate distance between phases (before energy storage of the mechanism)
mm
210±3
three
Moving contact overtravel
mm
40±2
four
Auxiliary hoe opening distance
mm
one hundred and fifty
five
Synchronization of three-phase opening and closing
ms
<3
six
Just divided speed
ms
>2.8
>2.8
seven
Just closed speed
ms
>3.8
eight
Distance between metal valve and conductive tube
mm
>125
nine
Grounding switch fracture distance
mm
>150
ten
main circuit resistance
μΩ
<120
<300
eleven
Maximum operating force distance
Nm
<160


Installation dimensions of FN11-12RD series high-voltage load switch

FN11-12RD series high-voltage load switch