Z series multi turn ordinary thrust valve electric deviceDetailed product description:Column tabs
Product Description

The Z-series multi turn ordinary thrust type valve electric device is equipped with a thrust disc, and the output torque is converted into output thrust through the valve stem nut in the thrust disc. The Z series electric installation is suitable for gate valves, globe valves, diaphragm valves, plunger valves, throttle valves, water gates, etc. Can be used for both open stem valves and concealed stem valves.

Power supply: conventional, three-phase 380V (50Hz); Special, three-phase 660V, 415V (50Hz, 60Hz); Single phase 220V, 110V (50Hz, 60Hz)
Environmental temperature: -20~+60 ℃ (special orders -40~+80 ℃).
Relative humidity: ≤ 95% (at 25 ℃).
Protection type: Outdoor type used in places without flammable, explosive, and non corrosive media. There are two types of explosion-proof products, d Ⅰ and d Ⅱ BT4. d Ⅰ is suitable for non mining working faces in coal mines; DIIBT4 is used in factories and is suitable for explosive gas mixtures in environments of IIA and IIB levels T1 to T4. (See GB3836.1 for details)
Protection level: IP55 (special orders IP65, IP67).
Work schedule: Short 10 minutes (30 minutes for special orders).

Main performance parameters table of Z-series multi turn ordinary thrust valve electric device

Model

Nominal torque (N · m)

Nominal thrust (KN)

Maximum stem diameter (mm)

Maximum number of turns (turns)

Manual speed ratio

Output speed (r/min)

Motor power (KW)

Reference weight (Kg)

Z5

fifty

twenty

twenty-eight

sixty

1:1

twelve

zero point one two

twenty-eight

Z10

one hundred

forty

twenty-eight

sixty

1:1

24/36

0.25/0.37

forty-five

Z15

one hundred and fifty

24/36

0.37/0.55

fifty

Z20

two hundred

one hundred

forty

sixty

1:1

18/24

0.37/0.55

fifty-five

Z30

three hundred

18/24

0.55/0.75

fifty-eight

Z45

four hundred and fifty

one hundred and fifty

forty-eight

one hundred and twenty

1:1

(20:1)

24/36

1.1/1.5

one hundred and ten

Z60

six hundred

24/36

1.5/2.2

one hundred and twenty

Z90

nine hundred

two hundred

sixty

one hundred and twenty

1:1

(25:1)

24/36

2.2/3

one hundred and thirty-nine

Z120

one thousand and two hundred

24/36

3/4

one hundred and forty-two

Z180

one thousand and eight hundred

three hundred and twenty-five

seventy

one hundred and fifty

22.5:1

18/24

4/5.5

two hundred and fifty

Z250

two thousand and five hundred

18/24

5.5/7.5

two hundred and fifty-five

Z350

three thousand and five hundred

seven hundred

eighty

one hundred and fifty

20:1

18/24

7.5/10

three hundred and thirty

Z500

five thousand

18/24

10/15

three hundred and fifty


Note 1: Other speeds can be provided according to user requirements: 12/18/24/30/36/42/48/60 (r/min)
Note 2: When the product provides a four layer counter, the maximum number of rotations is 10 times the number of rotations in Table 1

Dimensions and appearance

model

H

H1

L1

L2

L3

F

F1

F2

F3

F4

ΦD

Z5

two hundred and seventy-one

ninety-six

one hundred and fifty-eight

two hundred and twenty-six

two hundred and forty-nine

one hundred and fifty-eight

two hundred and fifty-nine

three hundred and ten

three hundred and sixteen

Z10~Z30

three hundred and sixteen

one hundred and thirty

two hundred

two hundred and thirty-eight

two hundred and ninety-five

two hundred

two hundred and fifty-five

three hundred and seventeen

three hundred and forty-nine

three hundred and seventy-four

four hundred

Z45/Z60

four hundred and fifteen

one hundred and ninety-five

two hundred and seventy-seven

two hundred and seventy-seven

three hundred and ninety-four

two hundred and thirty

two hundred and seventy-five

three hundred and ninety-one

three hundred and sixty-nine

three hundred and ninety-four

four hundred and sixty

Z90/Z120

four hundred and fifty-three

one hundred and ninety-five

two hundred and eighty-one

two hundred and eighty-one

four hundred and twelve

two hundred and seventy-eight

three hundred and ten

four hundred and twenty-six

four hundred and four

four hundred and twenty-nine

five hundred and fifty-six

Z180/Z250

five hundred and eighty-five

two hundred and fifty

three hundred and twenty

three hundred and twenty

four hundred and seventy-four

two hundred and ninety-five

three hundred and sixty

four hundred and seventy-six

four hundred and fifty-five

four hundred and seventy-six

three hundred and twenty

Z350/Z500

seven hundred and seventeen

two hundred and eighty

three hundred and ninety-nine

three hundred and ninety-nine

one thousand and seventy-six

four hundred and thirty-three

four hundred and seventeen

four hundred and forty-two

four hundred and seventeen

five hundred and forty-two

five hundred and sixty-five

Dimensions of Z-series multi turn ordinary thrust type valve electric device

Note 1: L1 is outdoor type/explosion-proof type, L2 is integral type/integral explosion-proof type
Note 2: F1 is outdoor type, F2 is explosion-proof type, F3 is integral type, F4 is integral explosion-proof type/integral adjustable explosion-proof type

Z series multi turn ordinary thrust valve electric device
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference