The UDZ-01S, -02S, and 03S dual color electric contact level gauges use two sets of red and green light-emitting tubes to simulate water (green) and steam (red) in the display, clearly indicating the position of the water level in the container. The 01S type is a medium low pressure level gauge, the 02S type is a high pressure level gauge, and the 03S type is an ultra-high pressure level gauge. The entire set of instruments consists of a measuring cylinder and a secondary instrument.
The outstanding advantage of the dual color electric contact level gauge is that it can adapt to the variable parameter operation of the boiler, and can operate under variable parameter conditions such as boiler start and stop. The instruments can accurately display the water level in the control room. Due to its large cross-sectional area of the water level container and the cooling error caused by the temperature drop of the water column, it is much smaller than that of mica (glass) water level gauges. The water container of the electric contact level gauge is very close to the steam drum, and all electrical signals are transmitted from the electric contact to the secondary instrument. Therefore, this instrument not only has a small time delay, but also has no variation or scale error caused by mechanical transmission, and does not require error calculation and adjustment. Without the need for complex calibration devices, instrument maintenance and calibration are greatly simplified. The electric contact level gauge has a simple structure, small volume, and eliminates the need for bulky differential pressure gauges, pressure transmission conduits, and valves, reducing metal consumption and alleviating the labor intensity of workers during maintenance.
The UDZ-01S, 02S, and 03S dual color electric contact level gauges have the advantages of simple working principle and structure, low cost, intuitive display, reliable operation, convenient fault diagnosis and troubleshooting, and low maintenance.
The 03 type measuring cylinder has higher requirements for overall sealing performance and structural strength based on the ultra-high pressure and critical requirements of power units with a power output of over 300000 kW. Therefore, this structure selects reasonable materials, changes the traditional structure, and improves the safety factor during operation. At the same time, the new structure brings great convenience to installation and maintenance.
This instrument is mainly used to monitor the boiler drum water level, high-pressure heater, low-pressure heater, deaerator, evaporator, and condenser. The water level measurement of DC boiler start-up separator and dual water internally cooled generator water tank, as well as the liquid level measurement of other conductive liquids, is not applicable to flammable and explosive media.
The contacts of the dual color electric contact level gauge are insulated with ultra pure alumina ceramic tubes. There are several contacts for a single measurement, and several display points for the secondary instrument. In addition, the secondary discussion table also has functions such as over limit alarm, full water, and water shortage protection.
The UDZ-01S, 02S, 03S dual color electric contact level gauge display device adopts a new product of 5 × 5 planar light-emitting diode, which has the characteristics of long service life, low power consumption, high luminous flux, and bright display