Characteristics of SLF100 Magnetic Flip Plate Liquid Level Gauge
Simple, sturdy, and compact design
The bypass pipe and display part are isolated in terms of pressure and gas resistance
Can measure and indicate the liquid level of corrosive, flammable, toxic, high-temperature, agitated, and contaminated liquids
SL-CFB magnetic flip column display, no need for external power supply
Due to the use of highly corrosion-resistant materials, it can be applied to all industrial fields
The design pressure range is from full vacuum to 420 bar
The design temperature range is -160 ℃ to+450 ℃
Technical parameters
Model:
SL-CFB-../..-M....-V40 x 1- MRA
Bypass pipe: outer diameter 40x1mm
Top of bypass pipe: welded cap
Optional parts: - Breather plug BSP1/2 "- Breather valve - Breather flange
Bottom of bypass pipe: flange with drain plug BSP1/2 "
Optional parts: - Drain valve - Drain flange
Connection: Bypass side installation
Flange:
DN10 – DN25、PN6、DIN 2631
DN10 – DN25、PN16、DIN 2633
DN10 – DN25、PN40、DIN 2635
DN32 – DN100、DIN 2527
½″ – 4″,ANSI B 16.5
150lb or 300lb
Threaded or welded end
GM/...=internal thread/size
GN/...=external thread/size
S...=welding end/outer diameter
Center distance M: minimum 150mm to maximum 2000mm
Material: Stainless steel 316Ti (1.4571)
Rated pressure: maximum 16 bar (according to float design)
Temperature range: up to 150 ℃ (according to float design)
Float:
Model ZTS35/185
Material - Titanium
Specific gravity - minimum 800kg/m3 (modified)
Pressure - Maximum 16 bar
Temperature - Maximum 150 ℃
Model ZBS35/120
Material - Nitrile rubber
Specific gravity - minimum 800kg/m3 (modified)
Pressure - Maximum 6 bar
Temperature - Maximum 80 ℃
Magnetic flip column display: Model MRA-M
Model: SL-CFB -.../16-M... - PF63x3-MRA
Model: SL-CFB -.../16-M... - PP63x3-MRA
Model: SL-CFB -.../16-M... - P63x3-mRA bypass tube outer diameter 63x3mm
Top of bypass pipe: welded cap
Optional parts: - Threaded accessories - Ventilation valve - Ventilation flange
Bottom of bypass pipe: - threaded fittings
Optional parts: - Drain valve - Drain flange
Connection: Bypass side installation
Flange:
DN15 – DN50、PN16
Size: ISO/DIN
½″ – 2 ″,ANSI B 16.5,150Ib
Size: ANSI B 16.5
Material: UP-GF
Center distance M: minimum 200mm to maximum 4000mm
Material: PVDF, PP or PVC-U
Rated pressure: maximum 4 bar
Temperature range: PVDF up to 80 ℃
PP maximum 60 ℃
PVC up to 40 ℃
Float: Model Z. S
PF...=Material PVDF
PP...=Material PP
P...=Material PVC-U
Float length based on specific gravity
Magnetic flip column display: Model MRA-M
Selection Tips
To purchase a magnetic flap level gauge, the following parameters need to be determined in detail: measuring medium, installation method, liquid receiving medium, process connection method, nominal pressure, center distance, working temperature, output signal, whether explosion-proof is required, and range.
Installation Diagram