Product name: FZB21-12D/T630-20 Indoor High Voltage Vacuum Load Switch
specification: FZB21-12D/T630-20 Indoor High Voltage Vacuum Load Switch
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor high-voltage load switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


FZB21-12D/T630-20 Indoor High Voltage Vacuum Load SwitchDetailed product description:Column tabs
FZB21-12D/T630-20 indoor high-voltage vacuum load switch (hereinafter referred to as load switch) is a three-phase AC 50Hz household device. In the rated voltage 12KV power system, it serves as the protection and control of electrical facilities, used for breaking and closing load currents, closed-loop currents, and carrying overload currents. It can also open and close no-load long lines, no-load transformers, and capacitors.
Install a grounding switch with the ability to close short-circuit currents.
The operating mechanism can be manually or electrically operated, facilitating the remote control requirements of the power system.

The FZRN21-12D/T125-31.5 indoor high-voltage vacuum load switch fuse combination device (hereinafter referred to as the combination device) is composed of a load switch and a fuse. In addition to the function of a load switch, it also has a short-circuit protection function.
In the Chinese market, load switches have gradually replaced circuit breakers and have been widely used. Compared with circuit breakers, load switches are not only cheaper and easier to operate, but also have faster fault response when equipped with fuses, which is particularly effective in protecting transformers. Load switches have been favored by urban and rural users and are increasingly valued and welcomed by people.
2. Normal usage conditions
a) Surrounding air temperature: upper limit+40oC, lower limit -40oC;
b) Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;
c) Water vapor pressure: daily average not exceeding 2.2kPa, monthly average not exceeding 1.8kPa;
d) A place without fire, explosion hazard, serious pollution, chemical corrosion, and severe vibration.

3 Main Technical Parameters
3.1 Main technical parameters of load switch

serial number
parameter name
unit
data
one
rated voltage
kV
twelve
two
rated frequency
Hz
fifty
three
rated current
A
six hundred and thirty
four
Rated Active load breaking current
six hundred and thirty
five
Rated closed-loop breaking current
six hundred and thirty
six
5% rated active load breaking current
thirty-one point five
seven
Rated cable charging breaking current
ten
eight
Rated no-load transformer capacity
kVA
one thousand two hundred and fifty
nine
1-minute power frequency withstand voltage
Vacuum fracture, phase to phase, relative to ground
kV
forty-two
isolation gap
forty-eight
ten
Lightning impulse withstand voltage (peak value)
Vacuum fracture, phase to phase, relative to ground
seventy-five
isolation gap
eighty-five
eleven
4S rated short-time withstand current (thermal stability)
kA
twenty
twelve
Rated peak withstand current (dynamic stability)
kA
fifty
thirteen
Rated short-circuit closing current (peak)
fifty
fourteen
Rated current breaking times
time
ten thousand
fifteen
mechanical life
ten thousand
sixteen
Allowable wear thickness of vacuum arc extinguishing chamber contacts
mm
two
seventeen
Manual operating torque
N.m
≤200

3.2 Technical parameters of composite electrical appliances

serial number
parameter name
unit
data
one
rated voltage
kV
twelve
two
rated frequency
Hz
fifty
three
Maximum rated current of fuse
A
one hundred and twenty-five
four
Rated breaking AC current
three thousand one hundred and fifty
five
The opening time of the switch triggered by the fuse
ms
40±5
six
Rated short-circuit breaking current (effective value)
kA
thirty-one point five
seven
Rated short-circuit breaking current (peak)
kA
fifty
eight
1-minute power frequency withstand voltage
Vacuum fracture, phase to phase, relative to ground
kV
forty-two
nine
isolation gap
forty-eight
Lightning impulse withstand voltage (peak value)
Vacuum fracture, phase to phase, relative to ground
seventy-five
ten
isolation gap
eighty-five
Fuse impactor output energy
J
2-5

3.3 Mechanical adjustment parameters

serial number
parameter name
unit
data
one
Contact opening distance/overtravel
mm
10±1/4±0.5
two
Average closing speed/average opening speed (contact just opened 6mm)
m/s
0.6±0.2/1.1±0.2
three
Synchronization of three-phase contact opening and closing/contact closing bounce time
ms
≤2/≤2
four
Distance between charged bodies and air to ground
mm
≥125
five
Main circuit resistance of upper and lower brackets
μΩ
≤70


4. FZB21-12D/T630-20 Indoor High Voltage Vacuum Load Switch Appearance and Installation Dimensions

FZB21-12D/T630-20 Indoor High Voltage Vacuum Load Switch Appearance and Installation Dimensions

Installation dimensions of FZB21-12D/T630-20 indoor high-voltage vacuum load switch

FZB21-12D/T630-20 Indoor High Voltage Vacuum Load Switch

FZB21-12D/T630-20 Indoor High Voltage Vacuum Load Switch