FLRN36-1D/125-50 indoor AC high voltage load switch fuse combination device (referred to as combination device) is a new type of load switch fuse combination device designed and manufactured based on the mature experience of existing combination device production in China and advanced foreign technology. It is a supporting equipment for HXGN-12 AC metal enclosed ring network switchgear, which can meet the needs of power system users in various regions. It has the advantages of simple structure, low maintenance, strong arc extinguishing ability, high insulation level of the fracture surface, and high reliability. The product meets the requirements of standards such as GB16926 and GB/T11022.
FLRN36-1D/125-50 Indoor AC High Voltage Load Switch Fuse Combination Electrical Outline and Installation Drawing:
Three main technical parameters:
|
serial number |
name |
unit |
load switch |
combined electrical apparatus | ||
|
one |
rated voltage |
KV |
twelve |
twelve | ||
|
two |
rated current |
A |
six hundred and thirty |
one hundred and twenty-five | ||
|
three |
rated frequency |
Hz |
fifty |
fifty | ||
|
four |
Rated short-circuit closing current (peak) |
KA |
fifty |
/ | ||
|
five |
Rated short-time withstand current |
twenty |
/ | |||
|
six |
Rated peak withstand current |
fifty |
/ | |||
|
seven |
Rated short-circuit duration |
S |
four |
/ | ||
|
eight |
Rated Active load breaking current |
A |
six hundred and thirty |
/ | ||
|
nine |
Rated closed-loop breaking current |
A |
six hundred and thirty |
/ | ||
|
ten |
Rated cable charging current |
ten |
/ | |||
|
eleven |
5% rated active load breaking current |
thirty-one point five |
/ | |||
|
twelve |
Rated short-circuit breaking current |
KA |
/ |
fifty | ||
|
thirteen |
Rated transfer current |
A |
/ |
one thousand five hundred and fifty | ||
|
fourteen |
Rated insulation level | 1-minute power frequency withstand voltage | Pole to pole, pole to ground |
KV |
forty-two |
forty-two |
| isolation gap |
forty-nine |
forty-nine | ||||
| Lightning impulse withstand voltage | Pole to pole, pole to ground |
seventy-five |
seventy-five | |||
| isolation gap |
eighty-five |
eighty-five | ||||
|
fifteen |
Each pole circuit resistance |
μΩ |
≤ 70 (excluding fuse resistance) |
|||
|
sixteen |
Mechanical lifespan of load switch |
time |
two thousand |
two thousand | ||
|
seventeen |
Rated short-time withstand current of grounding switch |
KA |
twenty |
twenty | ||
|
eighteen |
Rated peak withstand current of grounding switch |
fifty |
fifty | |||
|
nineteen |
Rated short-circuit duration of grounding switch |
S |
four |
four | ||
|
twenty |
Rated short-circuit closing current of grounding switch |
KA |
fifty |
fifty | ||
|
twenty-one |
Mechanical lifespan of grounding switch |
time |
two thousand |
two thousand | ||
FLRN36-1D/125-50 Indoor AC High Voltage Load Switch Fuse Combination Electrical Appliance