Overview
The UHS-Q dual color glass plate level gauge is an updated product of the UHS ordinary glass plate level gauge. It adopts flange connection and is used for liquid level indication in atmospheric pressure or open containers in various industrial systems, especially for on-site indication of colorless and transparent liquids, such as water, liquid ammonia, light oil, liquefied gas and other media.
structural principle
The dual color principle of the UHS-Q dual color glass plate liquid level gauge is based on the different reflection and refraction characteristics of light, and with the help of a color filter, this characteristic is made into a certain color, so as to achieve a dual color display where the liquid phase appears green (or black) and the gas phase appears red, and the gas-liquid interface is extremely clear.
|
level gauge section number |
|
Transparent size L1×16(mm) |
Transparent size L2(mm) |
Weight (Kg) |
|
Standard Type |
Jacket type |
|
one |
five hundred and fifty |
262×16
|
two hundred and sixty-two |
nineteen |
twenty-one |
|
two |
eight hundred and fifty |
five hundred and sixty-two |
thirty |
thirty-two |
|
three |
one thousand one hundred and fifty |
eight hundred and sixty-two |
forty-three |
forty-six |
|
four |
one thousand four hundred and fifty |
one thousand one hundred and sixty-two |
fifty-four |
fifty-nine |
|
five |
one thousand seven hundred and fifty |
one thousand four hundred and sixty-two |
sixty-four |
seventy-two |
Technical Requirements
Measurement range (installation center distance, L): 500, 800, 1100, 1400, 1700mm
Visual range: H=L-260
Nominal pressure: 4.0MPa
Working temperature: -20~250 ℃
Needle valve type automatic closing pressure: 0.3MPa
Heat tracing steam pressure: 0.6MPa
Heat tracing steam jacket joint: G1/2 "(external thread).
Connecting flange: A: HG20592-97 flat flange B: HG20592-97 convex flange
example
UHS-Q-AT2.5-I-800: Dual color glass plate level gauge, nominal pressure 2.5MPa, Class I carbon steel material, ordinary protruding flange, center distance 800.
Ordering Instructions
Please specify when placing an order:
Model, specification, measurement range
Work pressure and humidity
Material and connection method
Are additional accessories supplied.