HomeYour location:Homeinstrumentation and metersflow meterElectromagnetic Flowmeter → LDE Stainless steel electromagnetic flowmeter
Column tabs 
Product name: LDE Stainless steel electromagnetic flowmeter
specification: LDE Stainless steel electromagnetic flowmeter
  Zoom Zoom in on the image
Category: instrumentation and meters -- Electromagnetic Flowmeter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


LDE Stainless steel electromagnetic flowmeterDetailed product description:Column tabs
LDE intelligent electromagnetic flowmeter is an induction instrument that measures the volume flow rate of conductive medium inside a tube based on Faraday's law of electromagnetic induction. It adopts embedded technology of single-chip microcomputer to achieve digital excitation, and adopts CAN fieldbus on the electromagnetic flowmeter, which is the first of its kind in China and the technology has reached the leading level in China.
The LDE electromagnetic flowmeter can not only meet on-site display requirements, but also output 4-20mA current signals for recording, regulation, and control. It has been widely used in industrial technology and management departments such as chemical, environmental protection, metallurgy, medicine, papermaking, and water supply and drainage.
In addition to measuring the flow rate of general conductive liquids, LDE electromagnetic flowmeters can also measure the volumetric flow rate of liquid-solid two-phase flow, high viscosity liquid flow, and salt, strong acid, and strong alkali liquids.

Performance characteristics:
The instrument structure is simple, reliable, without moving parts, and has a long working life.
No flow blocking components, no pressure loss or fluid blockage.
No mechanical inertia, fast response, good stability, can be applied to automatic detection, adjustment, and program control systems.
The measurement accuracy is not affected by the type of measured medium and its physical parameters such as temperature, viscosity, density, pressure, etc.
Different combinations of PTFE or rubber lining materials and electrode materials such as Hc, Hb, 316L, Ti can adapt to the needs of different media.
There are various flow meter models available, including pipeline type and plug-in type.
Using EEPROM memory, the storage of measurement and operation data ensures safety and reliability.
It has two types: integrated and separated.
High definition LCD backlit display.

Technical parameters
Instrument accuracy: pipeline type 0.5 level, 1.0 level; Insertion type 2.5 level
Measurement medium: various liquid and liquid-solid two-phase fluids with conductivity greater than 5 μ S/cm.
Flow velocity range: 0.2-8m/s
Work pressure: 1.6MPa
Environmental temperature: -40 ℃ to+50 ℃
Medium temperature: PTFE lining ≤ 180 ℃
Rubber material lining ≤ 65 ℃
Explosion proof mark: Exmibd Ⅱ BT4
Explosion proof certificate number: GYB01349
External magnetic interference: ≤ 400A/m
Shell protection: integrated type: IP65;
Detached type: Sensor IP68 (5 meters underwater, limited to rubber lining)
Converter IP65
Output signal: 4-20mA.DC, load resistance 0-750 Ω
Communication output: RS485 or CAN bus
Electrical connection: M20 × 1.5 internal thread, φ 10 cable hole
Power supply voltage: 90-220V.AC, 24 ± 10% V.DC
Maximum power consumption: ≤ 10VA

Instrument selection
Range confirmation
The flow rate of the medium measured by the general industrial electromagnetic flowmeter should be 2-4m/s. In special circumstances, the minimum flow rate should not be less than 0.2m/s and the maximum should not be greater than 8m/s. If the medium contains solid particles, the commonly used flow rate should be less than 3m/s to prevent excessive friction between the lining and the electrode; For viscous fluids, the flow velocity can be chosen to be greater than 2m/s. A higher flow velocity helps to automatically eliminate the effect of viscous substances attached to the electrode, which is beneficial for improving measurement accuracy.
Under the condition that the range Q has been determined, the size of the flowmeter diameter D can be determined based on the range of flow velocity V mentioned above, and its value can be calculated by the following formula:
Q=πD2V/4
Q: Flow rate (㎡/h) D: Inner diameter of pipeline V: Flow rate (m/h)
The range Q of the electromagnetic flowmeter should be greater than the expected maximum flow value, while the normal flow value should be slightly greater than 50% of the flowmeter's full-scale scale.

Reference flow range

Caliber (mm)
Flow range (m3/h)
Caliber (mm)
Flow range (m3/h)
φ15
0.06~6.36
φ450
57.23~5722.65
φ20
0.11~11.3
φ500
70.65~7065.00
φ25
0.18~17.66
φ600
101.74~10173.6
φ40
0.45~45.22
φ700
138.47~13847.4
φ50
0.71~70.65
φ800
180.86~18086.4
φ65
1.19~119.4
φ900
?228.91~22890.6
φ80
1.81~180.86
φ1000
?406.94~40694.4
φ100
2.83~282.60
φ1200
553.90~55389.6
φ150
6.36~635.85
φ1600
723.46~72345.6
φ200
11.3~1130.4
φ1800
915.62~91562.4
φ250
17.66~176.25.
φ2000
1130.4~113040.00
φ300
25.43~2543.40
φ2200
1367.78~136778.4
φ350
34.62~3461.85
φ2400
1627.78~162777.6
φ400
45.22~4521.6
φ2600
1910.38~191037.6

Type spectrum

model
caliber
LDE
15~2600
code name
electrode material
K1
316L
K2
HB
K3
HC
K4
titanium
K5
Tantalum
K6
Platinum alloy
K7
Stainless steel coated with tungsten carbide
code name
Lining material
C1
Polytetrafluoroethylene F4
C2
Perfluoroethylene propylene F46
C3
Polyfluoroethylene FS
C4
Polyvinyl rubber
C5
Polyurethane rubber
code name
function
E1
Level 0.3
E2
Level 0.5
E3
Level 1
F1
4-20Madc, Load ≤ 750 Ω
F2
0-3kHz, 5V active, variable pulse width, output high-end effective frequency
F3
RS485 interface
T1
Room temperature type
T2
high-temperature type
T3
Ultra high temperature type
P1
1.0MPa
P2
1.6MPa
P3
4.0MPa
P4
16MPa
D1
220VAC±10%
D2
24VDC±10%
J1
Integrated structure
J2
Split type structure
J3
Explosion proof integrated structure

LDE Stainless steel electromagnetic flowmeter
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference