HomeYour location:Homeinstrumentation and metersflow meterturbine flow meter → LWGY-A/B/C series turbine flowmeter
Column tabs 
Product name: LWGY-A/B/C series turbine flowmeter
specification: LWGY-A/B/C series turbine flowmeter
  Zoom Zoom in on the image
Category: instrumentation and meters -- turbine flow meter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


LWGY-A/B/C series turbine flowmeterDetailed product description:Column tabs
1、 Overview
The LWGY (JG109) series turbine flowmeter is a new generation of turbine flowmeter that has been optimized and designed based on advanced technology of flow meters at home and abroad. It has the characteristics of simple structure, lightweight, high accuracy, good reproducibility, sensitive response, and easy installation, maintenance, and use. It is widely used to measure liquids in closed pipelines that do not corrode stainless steel 1Cr18Ni9Ti, 2Cr13, corundum AI2O3, and hard alloys, and have no impurities such as fibers or particles. The liquid with a kinematic viscosity of less than 5 × 10-6m2/s at working temperature can be used after real liquid calibration of the flowmeter for liquids with a kinematic viscosity greater than 5 × 10-6m2/s If paired with display instruments with special functions, it can also perform quantitative control, over limit alarm, etc., making it an ideal instrument for flow measurement and energy conservation

2、 Product Features
·High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;
·Good repeatability, short-term repeatability can reach 0.05%~0.2%, precisely due to its good repeatability, such as regular calibration or online calibration can be obtained
High precision flow meters are preferred for trade settlement;
·Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;
·Can obtain high frequency signals (3-4kHz) with strong signal resolution;
·Wide range, with a medium to large caliber of up to 1:20 and a small caliber of 1:10;
·Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;
·Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;
·There are various types of specialized sensors that can be designed according to the specific needs of users, such as low-temperature, bidirectional, and downhole sensors
Type, sand mixing special type, etc;
·Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance.

3、 Instrument classification
According to the classification of instrument functions, the LWGY series turbine flowmeter can be divided into two categories, namely:
Turbine flow sensor/transmitter
Intelligent integrated turbine flowmeter
2. Function Description
Turbine flow sensor/transmitter

The LWGY-A/B/C series turbine flowmeter products themselves do not have on-site display function and only transmit and output flow signals remotely. Flow signals can be divided into pulse signals or current signals (4-20mA); The instrument is inexpensive, highly integrated, and compact in size, making it particularly suitable for use with computer control systems such as secondary displays, PLCs, and DCS.
This type of turbine flow product is divided into two types: basic type and explosion-proof type (ExdIIBT6), as shown in the diagram

LWGY-A/B/C series turbine flowmeter outline drawing 1LWGY-A/B/C series turbine flowmeter outline drawing 2
Figure 1 Basic type sensor/transmitter Figure 2 Explosion proof type sensor/transmitter

According to different output signals, this type of product can be divided into LWGY - □ N type and LWGY - □ A type
LWGY - □ N type sensor: powered by 12-24VDC, three wire pulse output, high level ≥ 8V, low level ≤ 0.8V; signal transmission distance ≤ 1000 meters;
LWGY - □ A type transmitter: 24VDC power supply, two-wire 4-20mA output, signal transmission distance ≤ 1000.

Intelligent integrated turbine flowmeter

LWGY-A/B/C series turbine flowmeter outline drawing 3

Figure 3 Intelligent integrated turbine flowmeter

A new intelligent instrument integrating turbine flow sensor and display integration developed using advanced ultra-low power single-chip microcomputer technology, with dual row LCD on-site display, has obvious advantages such as compact structure, intuitive and clear reading, high reliability, no external power interference, lightning resistance, and low cost. The instrument has three-point correction of instrument coefficient, intelligent compensation of instrument coefficient nonlinearity, and can be corrected on site. The high-definition LCD display simultaneously displays instantaneous flow rate (4 significant digits) and cumulative flow rate (8 significant digits, with reset function). Keep all valid data intact for 10 years after power failure. This type of turbine flowmeter is an explosion-proof product with an explosion-proof rating of ExdIIBT6.

This type of turbine flowmeter can be divided into LWGY - □ B type and LWGY - □ C type according to the power supply method and whether it has remote signal output.
LWGY - □ B type: The power supply uses a 3.2V10AH lithium battery (which can operate continuously for more than 4 years); No signal output function.
LWGY - □ C type: The power supply adopts 24VDC external power supply, outputs 4-20mA standard two-wire current signal, and can add RS485 or HART communication according to different on-site needs.
Technical parameters

1. Basic parameters: Table 1

Instrument diameter (mm) and connection method

accuracy class

turndown ratio

Instrument material

Temperature of the tested medium (℃)

environmental conditions

output signal

power supply

Signal transmission line

transmission distance

Signal line interface

Explosion-proof rating

Protection level

4. 6, 10, 15, 20, 25, 32, 40 are connected by threads
(15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges
± 1% R, ± 0.5% R, ± 0.2% R (to be customized)
1:10:1:15:1:20
304 stainless steel, 316 (L) stainless steel, etc
-20~+120℃
Temperature -10~+55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106Kpa
Sensor: Pulse frequency signal, low level ≤ 0.8V, high level ≥ 8V
Transmitter: two-wire 4-20mADC current signal
Sensor:+12VDC,+24VDC (optional)
Transmitter:+24VDC
On site display type: The instrument comes with a 3.2V lithium battery or+24VDC external power supply
STVPV3 × 0.3 (three wire system), 2 × 0.3 (two wire system)
≤1000m
Basic type: Hausman connector or self-contained three core cable; Explosion proof type: Internal thread M20 × 1.5
Basic type: non explosion proof product; Explosion proof type: ExdIIBT6
IP65

2. Measurement range and working pressure
Table 2

Instrument caliber
(mm)
Normal flow range
(m3/h)
Expand traffic range
(m3/h)
Conventional connection method
Compared to the withstand voltage level
Specially designed pressure resistance level (MPa)
(with diameter flange connection method)
DN 4 0.04~0.25 0.04~0.4
Threaded connection/6.3MPa 10. 16, 25
DN 6 0.1~0.6 0.06~0.6 Threaded connection/6.3MPa 10. 16, 25
DN 10 0.2~1.2 0.15~1.5 Threaded connection/6.3MPa 10. 16, 25
DN 15 0.6~6 0.4~8 Threaded connection/6.3MPa 4.0, 6.3, 12, 16, 25
flange connection
DN 20 0.8~8 0.45~9 Threaded connection/6.3MPa 4.0, 6.3, 12, 16, 25
flange connection
DN 25 1~10 0.5~10 Threaded connection/6.3MPa 4.0, 6.3, 12, 16, 25
Flange connection/2.5MPa
DN 32 1.5~15 0.8~15 Threaded connection/6.3MPa 4.0, 6.3, 12, 16, 25
Flange connection/2.5MPa
DN 40 2~20 1~20 Threaded connection/6.3MPa 4.0, 6.3, 12, 16, 25
Flange connection/2.5MPa
DN 50 4~40 2~40 Flange connection/2.5MPa 4.0, 6.3, 12, 16, 25
DN 65 7~70 4~70 Flange connection/2.5MPa 4.0, 6.3, 12, 16, 25
DN 80 10~100 5~100 Flange connection/2.5MPa 4.0, 6.3, 12, 16, 25
DN 100 20~200 10~200 Flange connection/2.5MPa 4.0, 6.3, 12, 16, 25
DN 125 25~250 13~250 Flange connection/1.6MPa 2.5, 4.0, 6.3, 12, 16
DN 150 30~300 15~300 Flange connection/1.6MPa 2.5, 4.0, 6.3, 12, 16
DN 200 80~800 40~800 Flange connection/1.6MPa 2.5, 4.0, 6.3, 12, 16

Selection of LWGY-A/B/C series turbine flow meters
Table 3

model

explanation
LWGY─

/□

/□

/□

/□

/□

/□

nominal
path
four

4mm

six

6mm

ten

10mm

fifteen

15mm

twenty

20mm

twenty-five

25mm

thirty-two

32mm

forty

40mm

fifty

50mm

sixty-five

65mm

eighty

80mm

one hundred

100mm

one hundred and twenty-five

125mm

one hundred and fifty

150mm

two hundred

200mm

Type

N

Sensor type:+12V or 24V power supply, output three wire pulse signal

A

Transmitter type:+24V power supply, output two-wire 4-20mA

B

Intelligent type: Powered by lithium batteries, no signal output displayed on site

C

Intelligent type:+24V power supply, on-site display and output of two-wire 4-20mA

C1

Intelligent type:+24V power supply, on-site display and equipped with RS485 communication protocol

C2

Intelligent type:+24V power supply, on-site display with HART communication protocol

accuracy class

05

Level 0.5

ten

Level 1.0

02

0.2 level (negotiated ordering, longer production cycle)

Turbine
Type

W

Expand measurement range

S

Standard measurement range

material

S

304 stainless steel

L

316 (L) stainless steel

Explosion proof

N

Non explosion proof type

E

Explosion proof type, Exd Ⅱ BT6

pressure rating

N

Conventional (refer to Table 2)

H(x)

High voltage (refer to Table 2)


Note: DN15 to DN40 are usually threaded connections. If you wish to use flange connections, please add "(FL)" after "nominal diameter"
For example, a flange connected explosion-proof turbine flowmeter is selected to measure diesel fuel. The pipeline is DN40, and the current signal needs to be displayed and transmitted remotely on site. The accuracy is required to be level 0.5, made of 304 stainless steel, and the instrument has a pressure resistance of 16MPa. The measurement range is the standard range, and the product model should be LWGY-40 (FL)/C/05/S/E/H16

installation dimensions

The installation method of sensors varies depending on the specifications, using threaded or flange connections. The installation methods are shown in Figure 6, Figure 7, and Figure 8, and the installation dimensions are shown in Table 4.

LWGY-A/B/C series turbine flowmeter external dimensions
Figure 6
LWGY-A/B/C series turbine flowmeter installation size 1
LWGY-A/B/C series turbine flowmeter installation size 2

Figure 7 and Figure 8

Figure 4: DN4 to DN10
Dimensional drawing of threaded connection type turbine flow sensor (including straight pipe section)
Figure 5: DN15 to DN40
Dimensional drawing of threaded connection type turbine flow sensor
Figure 6: DN15 to DN200
Dimensional drawing of flange connected turbine flow sensor

Nominal diameter (mm)

L(mm)

G

D(mm)

d(mm)

number of holes

four

two hundred and ninety-five

G1/2

six

three hundred and thirty

G1/2

ten

four hundred and fifty

G1/2

fifteen

seventy-five

G1

Ф65

Ф14

four

twenty

eighty

G1

Ф75

Ф14

four

twenty-five

one hundred

G5/4

Ф85

Ф14

four

thirty-two

one hundred and forty

G2

Ф100

Ф14

four

forty

one hundred and forty

G2

Ф110

Ф18

four

fifty

one hundred and fifty

Ф125

Ф18

four

sixty-five

one hundred and seventy

Ф145

Ф18

four

eighty

two hundred

Ф160

Ф18

eight

one hundred

two hundred and twenty

Ф180

Ф18

eight

one hundred and twenty-five

two hundred and fifty

Ф210

Ф25

eight

one hundred and fifty

three hundred

Ф250

Ф25

eight

two hundred

three hundred and sixty

Ф295

Ф23

twelve


LWGY-A/B/C series turbine flowmeter

LWGY-A/B/C series turbine flowmeter
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference