HomeYour location:Homeinstrumentation and metersanalytical instrumentBiochemical Analysis → JZrO series zirconia oxygen analyzer
Column tabs 
Product name: JZrO series zirconia oxygen analyzer
specification: JZrO series zirconia oxygen analyzer
  Zoom Zoom in on the image
Category: instrumentation and meters -- Biochemical Analysis
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


JZrO series zirconia oxygen analyzerDetailed product description:Column tabs
purpose
The JZRO series zirconia oxygen analyzer is suitable for continuous monitoring of oxygen content in industrial furnace flue gas. It serves as a basis for operators to adjust the combustion air ratio or is connected to the automatic control system to achieve low oxygen and reasonable combustion, reduce fuel consumption, stabilize processes, improve product quality, and reduce environmental pollution. It has significant economic and social benefits.

Product Features
The probe is manufactured using nanotechnology, with a resolution of one hundred thousandth, short response time, excellent seismic and erosion resistance, and a long service life of the probe.
The oxygen electrode adopts pure platinum electrode, which effectively improves the electrical performance and activity of the probe.
Adopting high-temperature metal mesh filters overcomes the disadvantages of low penetration rate, easy blockage, poor thermal conductivity, and inconvenient cleaning of conventional ceramic filters.
The converter adopts a 16 bit processor and a fully isolated signal circuit. The menu style operation interface can provide standard 4-20mA corresponding outputs, upper and lower limit node outputs, RS485 communication, and convenient calibration operations for controlled temperature, oxygen content, oxygen potential, output, range, and nodes. The unique three parameter calibration of oxygen content can more accurately reflect the oxygen content at commonly used operating points.
The separately equipped heating transformer can significantly improve the service life and temperature control accuracy of the probe heating furnace.
The zirconia oxygen probe adopts active assembly, and the internal accessories can be replaced separately. Users may replace the oxygen sensor, electric furnace, thermocouple and other components separately.

Technical parameters

Oxygen measurement range Conventional 0-20.6%, 0-10%, or optional
Trace 0-2000ppm, 0-4000ppm, 0-1% or optional
Instrument accuracy The basic error of oxygen measurement in the system is ≤± 1.5% F • S
Accuracy of transmitter 1.0 level (≤ 1.0% F • S)
Temperature control accuracy 700 ± 1 ℃ at the constant temperature point
response time ≤ 2S (achieving 90% response)
alarm output Output of upper and lower limit nodes, "normally open" or "normally closed" points (optional)
output signal Oxygen content corresponding to 4mA~20mA (load 0W~750W)
Communication RS485 (Modbus RTU) (optional)
Scope of Background Correction -20mV~+20mV
System calibration method Three parameter online calibration
System correction method Menu style. Can control temperature, oxygen content, and oxygen potential
Online maintenance of parameters such as "4-20mA output", "range", "upper and lower limits", etc
Digital display format LED four digit digital display or LCD display
power supply AC200V± 15%(187VAC~253VAC)
power waste 6
heating power About 50W (average) can provide 150W output power
environmental conditions Temperature 0-50 ℃, relative humidity<90%
Protection level IP65
weight Detector weighs about 10kg, converter weighs about 5kg
material SUS321 stainless steel or SUS316/L stainless steel


Specification selection of JZrO series zirconia oxygen analyzer

Selection Table of JZrO Series Zirconia Oxygen Analyzer

JZrO series zirconia oxygen analyzer

JZrO series zirconia oxygen analyzer
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference