I. Overview
The UTG7000 split type ultrasonic level gauge is an intelligent non-contact level measuring instrument. The product has automatic power adjustment, gain control, temperature compensation, and adopts advanced detection and calculation technology to improve the measurement accuracy of the instrument. It also has a suppression function for interference echoes to ensure the authenticity of the measurement results. The product can be widely used for measuring the liquid level of various liquids and the height of solid materials, as well as for measuring distance.
2、 Main parameters of UTG7000 split type ultrasonic level gauge
Application: Liquid level measurement in various industrial fields, especially in wastewater treatment, acid and alkaline liquid measurement
Measurement of solid level and level difference in various industrial fields, such as coal piles, rocks, etc
Measurement range: Liquid: 0-40m Solid: 0-40m
Signal output: 4-20mA (16 bit D/A conversion), RS485 (choose one)
Switch signal: Four point switch output (upper limit, upper limit, lower limit, lower limit); 220VAC/1A
Display: Large backlit LCD display
Resolution: Range<15m, 1mm; Range>15m, 1cm
Accuracy: Based on standard plane ± 0.25-0.5% FS
Blind spot: 0.3m-1m
Power supply: 24VDC or 220VAC
Process connection: M66 × 2 or M75 × 2 (ultrasonic probe)
Environmental temperature: -40... 70 ° C
Host installation method: wall mounted, 6-digit LCD display
Material of transducer housing: standard type: ABS; Anti corrosion type: polytetrafluoroethylene
Protection level: transmitter IP65, sensor IP67
3、 UTG7000 Split Ultrasonic Level Gauge Selection Table
|
Product Name |
|
|
UTG7000 |
Split type ultrasonic level gauge |
|
|
code |
measurement range |
|
|
-X |
Material distance or liquid level height |
|
|
|
code |
measuring medium |
|
|
|
Y |
liquid |
|
|
|
W |
solid |
|
|
|
|
code |
Corrosion protection requirements |
|
|
|
|
N |
standard product |
|
|
|
|
F |
Anti corrosion type - polytetrafluoroethylene |
|
|
|
|
|
code |
output signal |
|
|
|
|
|
I |
4-20mA |
|
|
|
|
|
H |
RS232/RS285 |
Using tetrafluoroethylene sensors, it can be used in various corrosive environments.