The HPF integrated orifice flowmeter is a high range ratio differential pressure flow device composed of a standard orifice plate and a multi parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter, and pressure transmitter). It can measure the flow of gas, steam, liquid, and natural gas, and is widely used in process control and measurement in fields such as petroleum, chemical, metallurgical, power, heating, and water supply.
Scope of application
1. Nominal diameter: 15 mm ≤ DN ≤ 1200mm
2. Nominal pressure: PN ≤ 10MPa
3. Working temperature: -50 ℃ ≤ t ≤ 550 ℃
4. Range ratio: 1:10, 1:15
5. Accuracy: Level 0.5, Level 1
Selection of HPF series integrated orifice flowmeter
| model |
Instructions |
| HPF |
Throttle device (orifice flowmeter) |
|
code name |
Two basic classifications based on their structural features |
|
K |
orifice plate |
|
P |
Nozzles, etc |
|
code name |
Nominal pressure (105Pa) |
|
two point five |
two point five |
|
ten |
ten |
|
sixteen |
sixteen |
|
twenty-five |
twenty-five |
|
sixty-four |
sixty-four |
|
one hundred |
one hundred |
|
two hundred |
two hundred |
|
code name |
Caliber (mm) |
|
15~1200 |
15~1200mm |
|
code name |
Subdivide according to its structural form |
|
H |
Standard orifice plate (ring chamber) |
|
Y |
Standard orifice plate (flange) |
|
K |
Standard orifice plate (drilling) |
|
I |
ISA 1932 nozzle |
|
L |
Long diameter nozzle |
|
W |
Wenqiu Li nozzle |
|
G |
Classic Wenqiu Li Guan |
|
S |
Double orifice plate |
|
Q |
Circular perforated plate |
|
Z |
Conical inlet orifice plate |
|
R |
1/4 round hole plate |
|
P |
Eccentric orifice plate |