LGHX series annular orifice flowmeterDetailed product description:

I. Overview
The LGHX series annular orifice flowmeter is a throttling flow sensor developed by our company based on standard orifice plates. Due to its annular channel structure, various dirty media measured can easily pass through the annular gap between the orifice plate and the pipeline. Therefore, annular orifice flow meters are widely used for flow measurement of dirty media.
2、 Characteristics
1. Measure liquids or gases containing solid particles;
2. No need for long straight pipe sections, it can work under harsh pipeline conditions;
3. Suitable for measuring saturated steam, compressed air, coal gas, furnace exhaust gas, cooling water, condensate, various corrosive chemical solutions, and various fluid media;
4. Low pressure loss and low power consumption;
5. Stable outflow coefficient, high accuracy, and good reliability under harsh conditions;
3、 Technical parameters of LGHX series annular orifice flowmeter
1. Nominal diameter: DN50~DN3000
2. Working temperature: -200~450 ℃
3. Nominal pressure: -0.1~40MPa
4. Accuracy: 1.0%, 1.5%, 2.0%
5. Connection method: flange connection, welding connection