Product name: F400N series variable area flowmeter
specification: F400N series variable area flowmeter
  Zoom Zoom in on the image
Category: instrumentation and meters -- Other flow meters
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


F400N series variable area flowmeterDetailed product description:Column tabs
F400N series variable area flowmeter

Durable machined acrylic resin shell
Direct reading, permanent scale
Allow application in direct sunlight
Strengthening connection with metal thread support

The F400N series variable area flowmeter is made of high-quality polypropylene material through mechanical processing, polished to a crystal like finish, with internal parts resistant to corrosion and wear, a sturdy and well assembled adapter, and a fluororubber O-ring seal. The permanent scale is printed on the flowmeter housing via wire mesh, making it easy to read directly in front of the float.

In addition to standard specifications, users can choose variable area flow meters with other configurations and flow ranges. Please specify the required installation configuration, fluid to be measured, and measurement range when placing an order. The optional reading units are GPM (gallons per minute), LPM (liters per minute), or SCFM (cubic feet per minute).

The F400N series variable area flowmeter is tested and calibrated using water or air. If it is used to measure other chemicals, please fully consider its applicability to avoid damaging the flowmeter.

Installation Guide
1. Variable area flow meters must be installed in a strictly vertical plane to ensure measurement accuracy.
2. Seal all pipe threads with Teflon (or similar) tape, and do not use PVC adhesive or pipe coating on polypropylene materials, as even smoke may cause cracking. If installing a variable area flowmeter on a glued pipeline, wait until all glued joints are completely dry and the smoke inside the pipeline has been cleared. Do not use pliers or other similar tools to clamp the flow meter, and do not tighten it too tightly.
3. When installing walls, floors, or ceilings, they should be carefully aligned and stable. If necessary, it is recommended to use suitable brackets to keep the pipes aligned and prevent vibration.
4. Valve: Avoid installing in systems where there may be a surge in flow, as the surge in flow can cause the float to impact the stopper and damage the flow meter. Electromagnetic valves or other quick opening valves cannot be used unless protective measures are taken for the float flowmeter. If necessary, a surge chamber can be installed, which is useful in high-voltage start-up situations.
5. The maximum working pressure should not exceed the PSI value at the recommended fluid temperature.

Technical parameters of F400N series variable area flowmeter

Maximum work pressure

150 PSI(10.3 bar) @21℃

Maximum fluid temperature Polypropylene adapter: 65 ℃ @ 0 psi
PVC adapter and float: 49 ℃ @ 0 psi
Precision ±2% FS
Calibration liquid Water, specific gravity 1.0
Maximum pressure difference 2 PSI
Size F-400N: diameter 32mm, height 210mm, 230g
F-410N: diameter 45mm, height 280mm, 910g

Standard Configuration
***F-400N series standard variable area flowmeter
BWF425F-40250LN-4 Variable Area Flow Meter, Interface 1/4 "NPT (F), Flow Range 0.025-0.25 gpm (0.1-1.0 lpm), PVC Connector, PVC Float, User Manual
BWF450F-40050LN-4 Variable Area Flow Meter, Interface 1/4 "NPT (F), Flow Range 0.050-0.500 gpm (0.2-2.0 lpm), PVC Connector, 316 SS Float, User Manual
BWF401F-40375LN-8 Variable Area Flow Meter, Interface 1/2 "NPT (F), Flow Range 0.1-1.0 gpm (0.4-4.0 lpm), Polypropylene Connector, PVC Float, User Manual
BWF402F-40376LN-8 Variable Area Flow Meter, Interface 1/2 "NPT (F), Flow Range 0.2-2.0 gpm (1.0-7.5 lpm), Polypropylene Connector, 316 SS Float, User Manual
BWF403F-40377LN-8 Variable Area Flow Meter, Interface 1/2 "NPT (F), Flow Range 0.3-3.0 gpm (1.5-11.0 lpm), Polypropylene Connector, 316 SS Float, User Manual
BWF405F-40500LN-8 Variable Area Flow Meter, Interface 1/2 "NPT (F), Flow Range 0.5-5.0 gpm (2.0-20.0 lpm), Polypropylene Connector, 316 SS Float, User Manual
***F-410N series standard variable area flowmeter
BWF410F-40750LN-12 Variable Area Flow Meter, Interface 3/4 "NPT (F), Flow Range 1.0-10 gpm (4-38 lpm), Polypropylene Connector, 316 SS Float, User Manual
BWF417F-41017LN-12 Variable Area Flow Meter, Interface 3/4 "NPT (F), Flow Range 1.0-17 gpm (4-64 lpm), Polypropylene Connector, 316 SS Float, User Manual
BWF420F-41000LN-12 Variable Area Flow Meter, Interface 3/4 "NPT (F), Flow Range 2.0-20 gpm (8-80 lpm), Polypropylene Connector, 316 SS Float, User Manual
BWF421F-41000LN-16 Variable Area Flow Meter, Interface 1 "NPT (F), Flow Range 2.0-20 gpm (8-80 lpm), Polypropylene Connector, 316 SS Float, User Manual