Product name: ZFN16-12 series indoor AC high-voltage vacuum load switch
specification: ZFN16-12 series indoor AC high-voltage vacuum load switch
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor high-voltage load switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


ZFN16-12 series indoor AC high-voltage vacuum load switchDetailed product description:Column tabs
Overview

The ZFN16-12 indoor AC high-voltage load switch fuse combination (hereinafter referred to as the "series switch") is independently designed and developed by our factory. The performance meets the requirements of international standards GB3804-90 "3-63KV AC High Voltage Load Switch" and IEC420 "AC High Voltage Load Switch Fuse Combination Apparatus" (1990 edition) and national standards (draft for approval), and has the advantages of safe and reliable breaking, long electrical life, frequent operation, basically no maintenance required when breaking and shifting current, and obvious isolation fracture. The load switch fuse combination device also has the function of protecting transformers from overload and preventing equipment from running in phase loss.

purpose

The ZFN16-12 series switch is suitable for use in power grids with rated voltage of 6-12KV three-phase AC 50Hz, as a means of breaking load current, overload current, and short-circuit current. It is particularly suitable for places that require oil-free, non maintenance, and frequent operation. This product can be used with CS6-I type operating mechanism and CS □ manual operating mechanism.

ZFN16-12 series indoor AC high-voltage vacuum load switch model meaning

Model Description of ZFN16-12 Series Indoor AC High Voltage Vacuum Load Switch
Environmental conditions for use
a、 Altitude not exceeding 1000 meters;
b、 Upper limit of ambient air temperature+40oC lower limit -25oC;
c、 Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;
d、 The surrounding air should not be significantly polluted by corrosive or flammable gases, water vapor, etc;
e、 No frequent vigorous exercise;

serial number

name

unit

parameter

one

rated voltage

KV twelve
two

Maximum operating voltage

KV twelve
three

rated frequency

Hz fifty
four

rated current

A six hundred and thirty
five

Rated Active load breaking current

A six hundred and thirty
six

Rated closed-loop breaking current

A six hundred and thirty
seven

5% rated active load breaking current

A thirty-one point five
eight

Rated number of cable charging disconnections

A ten
nine

Rated capacitor breaking current

A four hundred
ten

Rated no-load transformer breaking current

A 6000KVA transformer no-load current
eleven

1-minute power frequency withstand voltage (effective value) to ground, phase to phase, vacuum break/isolation break

KV 42/48
twelve

Full wave lightning impulse withstand voltage (peak) to ground, phase to phase, vacuum break/isolation break

KV 75/85
thirteen

Rated short-time withstand current (thermal stability)

KV/S 20/3
fourteen

Rated peak withstand current (dynamic stability)

KA fifty
fifteen

Rated short-circuit closing current

KA fifty
sixteen

Rated current breaking times

time

ten thousand
seventeen

mechanical life

time

ten thousand
eighteen

Allowable cumulative thickness of contact wear

mm three
nineteen

Opening and closing operation torque (force)

Nm/(N) 175(350)

2. The technical parameters of the load switch fuse combination device are shown in the following table:

serial number

name

unit

parameter

one

rated voltage

KV twelve
two

Maximum operating voltage

KV twelve
three

rated frequency

Hz fifty
four

Maximum rated current of fuse

A one hundred and twenty-five two hundred
five

Rated transfer current

A two thousand three thousand one hundred and fifty
six

The opening time of the fuse triggered switch

ms 35±5
seven

Rated short-circuit breaking current (expected effective value)

KA thirty-one point five
eight

Rated short-circuit closing current (expected peak)

KA eighty
nine

1-minute power frequency withstand voltage (effective value) to ground, phase to phase, vacuum break/isolation break

KV 42/48
ten

Full wave lightning impulse withstand voltage (peak) to ground, phase to phase, vacuum break/isolation break

KA 75/85
eleven

Fuse impactor output energy

J 2-5

3. Technical parameters of fuses for combination electrical appliances (see table below)

model rated voltage Fuse rated current Rated breaking current Rated current of melt
SDLAJ twelve forty fifty 6.3,10,16,20,25,31.5,40
SFLAJ one hundred 50,63,71,80,100
SKLAJ one hundred and twenty-five one hundred and twenty-five

4. Technical parameters for assembly and adjustment of vacuum arc extinguishing chamber (see table below)

serial number project unit parameter
one contact gap mm 8+1
two Contact profile mm 3+1
three Average closing speed m/s 0.6±0.2
four Average opening speed m/s 1±0.2
five Non synchronous opening and closing of three-phase contacts ms ≤2
six Contact closing bounce time ms ≤2
seven Distance between charged bodies and relative ground mm ≥125
eight Main circuit resistance of upper and lower brackets μΩ ≤60


Outline drawing

Outline drawing of ZFN16-12 series indoor AC high-voltage vacuum load switch
1. Closing spring
2. Operating mechanism
3. Guiding sleeve
4. Adjust the screw sleeve
5. Opening buffer pad
6. Opening buffer spring
7. Bracket
9. Insulators
10 upper brackets
11. Vacuum arc extinguishing chamber
12. Insulation holder
13. Lower bracket
14 Insulated push-pull rod

ZFN16-12 series indoor AC high-voltage vacuum load switch installation size 1
1. Closing spring
2. Operating mechanism
3. Guiding sleeve
4. Adjust the bolt
5. Opening buffer pad
6. Opening spring
7. Bracket
8. Insulators
9. Isolation knife
10. Upper bracket
11. Vacuum arc extinguishing chamber
12. Insulation holder
13. Lower bracket
14. Insulated push-pull rod
15. Melting tube
16. Screw
17. Nut
18. Grounding knife

ZFN16-12 series indoor AC high-voltage vacuum load switch installation size 2

1. Combination appliance
2. Φ 20 steel pipe (to be provided by the user)
3. Bend connection
4. Operating mechanism
5. Operating handle
6. Connect

ZFN16-12 series indoor AC high-voltage vacuum load switch