HomeYour location:Homeinstrumentation and metersElectrical instrumentsVoltage loss timer → DT5-F/G Voltage Monitoring Instrument
Column tabs 
Product name: DT5-F/G Voltage Monitoring Instrument
specification: DT5-F/G Voltage Monitoring Instrument
  Zoom Zoom in on the image
Category: instrumentation and meters -- Voltage loss timer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


DT5-F/G Voltage Monitoring InstrumentDetailed product description:Column tabs
1: Overview
The DT5-F/G voltage monitoring instrument is a highly stable and reliable statistical instrument for power supply voltage quality. It can continuously measure the voltage signal of the power grid, perform statistical analysis and data storage, and is a high-tech electronic measuring instrument for monitoring and assessing the voltage quality of the power system. Suitable for working under three types of power supplies: AC1OOV, AC22OV, and AC38O. There are three series, DT5-1 can monitor - phase voltage or - line voltage; DT5-2 type can monitor two phase voltages or two line voltages; DT5-3 type can monitor three phase voltages or three line voltages; A large capacity E2 PROM is used to store collected data, enabling the instrument to store statistical data and power outage data for 12 months. In software design, modular and structured programming methods are adopted, and a combination of high-level languages and assembly languages is used to ensure that the program has both fast execution speed to meet real-time monitoring requirements and excellent maintainability. It also adopts SMT technology and new large-scale integrated circuit devices. Such as high-precision, low drift amplifiers, high-speed A/D converters, and single-chip display drivers, simplify circuit design. Multiple electromagnetic compatibility protection measures and surface mounting processes have improved the stability and reliability of the instrument.

2: Main performance
1. Measurement method:
True RMS measurement directly displays the instantaneous value of the measured voltage.
2. Statistical object:
It can collect, store, and perform statistical analysis on high voltage grid voltages above 3KV or low voltage signals of 220V and 380V that are converted to PT100V.
3. Statistical form:
The instrument detects voltage every second and calculates the average voltage for one minute. The instrument automatically classifies and calculates the voltage by day and month.
4. Statistical items and main functions:
Can store statistical data and power outage data for twelve months.
It can store voltage statistics and on-time data for any day of this month, last month, and the previous month, totaling three months.
A multimeter can record and store statistical data and voltage loss conditions for any individual line or phase.
Read the instantaneous voltage value, daily and monthly voltage qualification rate and qualification time, over limit rate and over limit time, maximum (minimum) value and occurrence time, average voltage and total operating time, power outage frequency (32 times per month) and the time of each power outage.
The upper row displays voltage values and percentages on a 4-digit 0.5-inch LED digital display; The lower row displays minutes, date, and time on a 6-digit 0.36-inch LED digital display.

3: Main technical indicators

working power supply
AC100V, AC220V, AC380V optional
measurement range
AC70V~AC130V(PT100V)
AC154V~AC286V(220V)
AC266V~AC494V(380V)
power consumption
<3VA
accuracy
measurement accuracy
<0.5%
nonlinearity
<0.1%
clock accuracy
< 1 second/24 hours
stability
Operating Temperature
-35℃~+60℃
temperature effect
100PPM/℃
long-term stability
<0.1%/year
working conditions
temperature
-35℃~60℃
humidity
20%~90% no condensation
data management
data storage
32K
Power outage data retention time
a decade
sampling period
Once per second
physical interface
RS232/RS485 (single choice)
communication protocol
101 CDT、Polling
Baud rate
2400bps, 4800bps, 9600bps (optional)
Other
Overall machine performance
Compliant with DL500-92
Electromagnetic Compatibility
Compliant with IEC61000
Lightning surge protection
Compliant with ITUK
Overall dimensions
140 × 190 × 60 (hanging type)
160 × 80 × 200 (embedded)
aperture size
φ 6.2mm (hanging type)
151 × 71 (embedded)
weight
0.9KG
Monitoring circuit
Route 1, Route 2, Route 3 (indicated by the user when placing an order)

DT5-F/G Voltage Monitoring Instrument
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference