| Product name: | YLVA-7010 series fan coil electric valve | ||||||
| specification: | ![]() |
||||||
| Category: | Pump valve fittings -- electric valve | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||

|
Name |
Model |
Caliber parameters |
L |
H |
Kv | |
|
Er Tong |
YLD-215 |
1/2″ |
DN15 |
ninety |
one hundred and fourteen |
four point five |
|
YLD-220 |
3/4″ |
DN20 |
ninety-five |
one hundred and sixteen |
five point seven | |
|
YLD-225 |
1″ |
DN25 |
one hundred and five |
one hundred and twenty-eight |
eight point seven | |
|
three-way electric valve |
YLD-315 |
1/2″ |
DN15 |
ninety |
one hundred and thirty-three |
four point three |
|
YLD-320 |
3/4″ |
DN20 |
ninety-five |
one hundred and thirty-three |
five point five | |
|
YLD-325 |
1″ |
DN25 |
one hundred and five |
one hundred and forty-four |
eight point three | |
6、 Wiring schematic diagram
7、 Installation diagram of YLVA-7010 series fan coil electric valve
8、 Installation and commissioning requirements for electric valves of fan coil units
1. Please read the instruction manual carefully before installation. It must be installed by professional technicians and wired strictly according to the wiring diagram.
2. The flow direction of the two-way electric valve medium can be from A to B, or from B to A; the flow direction of the three-way electric valve medium can be from AB to A or B
3. The driver can be installed at any angle, but it must be above the level of the valve body.
4. Never apply force to the drive during installation, otherwise it may damage the drive.
5. Never apply force to the valve stem when removing the valve body for installation, otherwise the valve stem may deform and cause water leakage.
6. This valve cannot be equipped with a three speed switch, only with a mechanical or electronic thermostat.
7. When debugging, it is necessary to observe whether the driver can reliably start or stop. If it continues to move up and down continuously, the driver must be replaced, otherwise the sealing life of the valve stem will be very short.
8. When the pull rod is in the upper position, manual operation can be used. By pushing the white manual pull rod downwards to the middle position and inward, the valve can be opened. Manually restore the valve to the closed position by gently lowering the white manual lever and pulling it out. When the power is restored, the valve and driver return to the automatic position.
9、 Attention to electric valve for fan coil unit:
If the valve is driven open by a motor, it cannot be manually closed unless the driver is removed.
To avoid trouble during product operation, the entire system should be flushed and a 50 micron (or finer) filtration device should be installed in the system before installation.
10、 Repair and maintenance of fan coil electric valve
1. If the valve is leaking, the fluid should be drained or isolated from the system.
2. Check if the valve core component needs to be replaced.
3. If the drive does not work or moves up and down continuously, the entire drive should be replaced.
11、 Important Notice:
1. Before installation, repair, and maintenance, the power must be cut off first.
2. When replacing the valve body or valve core, the fluid must be cut off first, and the air disc exhaust valve must be opened to completely relieve pressure before operation.
3. If the valve leaks during use, it must be immediately isolated from the system and drained of fluid.
4. Choosing a regular drive head, each thermostat can only be equipped with one electric valve, otherwise the manufacturer will not be responsible for any consequences caused.