4800 series split type electromagnetic flowmeterDetailed product description:Column tabs
The 4800 series split type electromagnetic flowmeter is an electromagnetic induction flow meter, which is a high-tech electromechanical product integrating signal detection and microelectronic intelligent technology

The converter adopts the latest and most advanced international microcontroller (MCU) and surface mount technology (SMT), with reliable performance, high accuracy, low power consumption, stable zero point, and convenient parameter setting.
Large screen LCD display, displaying cumulative flow rate, instantaneous flow rate, flow percentage, etc.
A bidirectional measurement system that can measure both forward and reverse flow rates. It can measure the volumetric flow rate of conductive liquid media, including highly corrosive liquids such as acids, alkalis, salts, as well as pulp, mud, wastewater, and solid-liquid two-phase suspensions.
The product is widely used in industries such as petroleum, chemical, metallurgical, textile, food, pharmaceutical, papermaking, as well as environmental protection, municipal, water conservancy, and river irrigation.

Technical parameters:
1. Measurement medium: Conductive liquid (including solid-liquid two-phase)
2. Accuracy: ± 0.5%, ± 1.0% (by caliber)
3. Dielectric conductivity: Normal measurement should not be less than 5 μ s/cm
4. Output signal: (0~5) kHz frequency programmable
(4~20) mA current signal (active/passive)
RS-485 communication (Modbus protocol), etc
5. Nominal diameter: DN10~DN3000mm
6. Explosion proof mark: Exd [ib] mIIBT4
7. Rated pressure: 0.25MPa~25MPa (by caliber)
≥ 16MPa high pressure type
8. Medium temperature: -25 ℃ -180 ℃ (classified by lining material)

4800 series split type electromagnetic flowmeter
Product Category