WMY Type Input Type Liquid Level TransmitterDetailed product description:Column tabs

WMY type input type liquid level transmitter

The WMY type diffusion silicon input type liquid level transmitter is a two-wire system, with 4-20mADC output and 24VDC DC power supply. The parts in contact with the medium are all made of stainless steel and can be directly installed on the measuring pipeline. It is extremely convenient to use and widely used for liquid level measurement in industries such as petroleum, chemical, metallurgy, environmental protection, food, water conservancy, urban water supply, and oil fields. The excellent quality of the liquid level transmitter meets the demand for high-precision liquid level detection instruments in China's industrial automation and some industries' measurement automation.  

1、 Characteristics
Good stability, high precision, high performance/price ratio
Directly put into the tested medium, installation and use are quite convenient
Solid state structure, no movable parts, high reliability, long service life
High precision measurements can be carried out on materials ranging from water and oil to viscous pastes, without being affected by foaming, sedimentation, or electrical characteristics of the measured medium
No material fatigue wear, insensitive to vibration and impact
Wide range temperature compensation
Equipped with reverse polarity protection and overload current limiting protection for power supply

2、 Working principle
Measurement principle using static pressure method
When the liquid level transmitter is inserted into a certain depth of the measured liquid, the pressure on the sensor facing the liquid level is: P=p.g.H+P·
In the formula:
P: Pressure exerted on the liquid surface of the sensor, unit: Pa
p: Density of the tested liquid, unit: kg/m3
g: Local gravity acceleration, unit: m/s2
P ·: Atmospheric pressure on the liquid surface, unit: Pa
H: Depth of liquid input into the sensor, unit: m
At the same time, the atmospheric pressure P · on the liquid surface is introduced into the back pressure chamber of the sensor through an air guiding cable to counteract the P · on the liquid surface of the sensor, so that the pressure measured by the sensor is: P=p.g.H
Obviously, by measuring the pressure P, the liquid level depth H can be obtained. The pressure signal sensed by the sensor is converted and amplified by the circuit, compensated, and output as a standard signal.

Wiring diagram of WMY type input liquid level transmitter

3、 Technical performance
Applicable media: The immersion type is suitable for media coexisting with 316 stainless steel, nitrile rubber, and polyvinyl chloride, while the flange type can measure non corrosive media.  
Measurement range: 0-0.1 meters to 0-35 meters
Accuracy: 0.25%; 0.5% 
Working temperature: -10 ℃ -+70 ℃ (medium without crystallization)
100% equally divided scale and LED indicator head, making on-site reading very convenient
Storage temperature: -40 ℃ -+125 ℃
Zero temperature coefficient: ± 0.015% range/℃
Range temperature coefficient: ± 0.015% Range/℃
Long term stability: ± 0.2% range/year
Power supply voltage: 12-36VDC standard 24VDC
Output signal: two-wire 4-20mADC
Maximum overload: not exceeding the length of the pipe

4、 Debugging method:
Unscrew the protective cover to see the zeroing and full range resistors. Connect an external standard power supply and ammeter (0.2 poles or more) to adjust them. The steps are as follows:
In the absence of liquid in the transmitter, adjust the zero point resistor to output a current of 4mA
Add liquid to the transmitter to full range, adjust the full range resistor to output a current of 20mA
Repeat the above steps two or three times until the signal is normal.  
After adjustment, tighten the protective cover.

5、 Structural characteristics

Shell:
1Cr18Ni9Ti
Main structural material:
polyethylene
Sensor form:
Oil filled core diffusion silicon sensor
dead weight:
Ordinary type 2kg, with digital display head type 2.5kg


6、 Electrical connection diagram:

Installation diagram of WMY type input liquid level transmitter

WMY Type Input Type Liquid Level Transmitter