| Product name: | T900F Electromagnetic flow converter | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Electromagnetic Flowmeter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
The T900F electromagnetic flow converter can be paired with the MT900F series electromagnetic flow sensor to form the MT900F series electromagnetic flow meter, which is used to measure the volumetric flow rate of conductive fluids such as acidic and alkaline corrosive media or liquid-solid two-phase media.
Product Features:
The machine is equipped with a self calibration device, which facilitates users to conduct regular calibration checks;
There are multiple functional options available for users to choose from;
Electrically isolated current output, easy to connect with instruments and systems (such as computers) that are grounded at the rear end;
Electrically isolated frequency output, suitable for direct connection with electronic counters;
Suitable for forward and reverse measurement (V/R type)
Technical specifications of T900F electromagnetic flow converter
Complete set accuracy: When the flow velocity V is within the range of 0.5-10m/s, the complete set accuracy is ± 0.5% of the measured value
Model and matching:
|
Converter model |
Supporting sensor caliber |
Remark |
|
T900F T900F/NF T900F/NF/NB |
φ10~450 φ500~1200 φ1300~3000 |
F is the on-site type F/NF is a field type NB is a power driven stage |