The LDG electromagnetic flowmeter consists of an LDG electromagnetic flow sensor and an LDZ-4A electromagnetic flow converter. It can be used to measure the volumetric flow rate of corrosive liquids such as acids, alkalis, and salts, as well as liquid-solid suspensions such as slurries, slurries, and pulp.
technical indicators
The LDG type electromagnetic flowmeter is a new product developed in recent years based on the LD type electromagnetic flowmeter. In addition to maintaining the characteristics of ordinary LD type electromagnetic flowmeters, it also has the following features:
Features:
The sensor is small, lightweight, structurally simple and reliable, with no moving parts inside and almost no pressure loss;
The sensor adopts a clip on installation, which is very convenient for installation, use, and maintenance.
Adopting low-frequency ternary rectangular wave excitation and sampling amplification technology, it has strong anti-interference ability, stable zero point, and reliable operation;
The power consumption is small, and the power consumption of the complete set of instruments is about 30VA, regardless of the diameter of the transmitter.
The precision of the complete set of instruments is relatively high.
Main technical indicators
Accuracy: ± 1% FS
Dielectric conductivity:>10-4S/cm
Output signal: 0-10mADC (load resistance 0-1.5k Ω)
4-20mADC (load resistance 0-750 Ω)
Environmental conditions: Temperature -10~55 ℃, humidity<85%
Maximum working pressure: 1.6Mpa
Working temperature:
|
Lining material |
Working temperature ℃ |
|
Polyurethane rubber
neoprene
Polytetrafluoroethylene |
0~60
0~80
0~130 |
Power supply: 220V 50Hz
Power consumption:<30VA
Sensor specifications
|
model |
LDG-25 |
LDG-50 |
LDG-80 |
LDG-100 |
|
Nominal diameter mm |
twenty-five |
fifty |
eighty |
one hundred |
|
Maximum flow rate m3/h |
|
16 40 twenty twenty-five thirty |
|
|
|
Weight kg |
three |
six |
nine point one |
thirteen point two |